Related Experiment Video
Updated: Jun 1, 2026

Preparation of Food Samples Using Homogenization and Microwave-Assisted Wet Acid Digestion for Multi-Element Determination with ICP-MS
Published on: December 22, 2023
Elimination of oxide interferences and determination of ultra-trace silver in soils by ICP-MS with ion-molecule
Wei Guo1, Shenghong Hu, Jiangyi Zhang
1Key Laboratory of Biogeology and Environmental Geology of Ministry of Education, Faculty of Earth Sciences, China University of Geosciences, Wuhan 430074, PR China. guowei012345@163.com
Abstract:
Silver is subject to significant spectral interferences caused by high concentrations of Zr, Nb, Mo and Y in inductively coupled plasma mass spectrometry (ICP-MS) analysis for soil or sediment samples. In this study, the Zr, Nb, and Mo based oxide and/or hydroxide polyatomic interferences were successfully eliminated by ion-molecule reactions in a dynamic reaction cell (DRC). These potentially interfering ions ⁹³Nb¹⁶O+, ⁹²Zr¹⁶OH+ and ⁹²Mo¹⁶OH+ on ¹⁰⁹Ag+ were rapidly oxidized to higher oxides ⁹³NbO₂+, ⁹²ZrO₂H+/⁹²ZrO₂H+ and ⁹²MoO₂H+ by O₂ as the reaction gas in DRC. However, interfering ions ⁸⁹Y¹⁸O+ and ⁹¹Zr¹⁶O+ on ¹⁰⁷Ag cannot be removed by this method, because the reaction rates of ZrO+ and YO+ to ZrO₂+/ZrO₃+ and YO₂+/YO₃+ were too low. Under the optimized O₂ flow rate (2.4 mL min⁻¹) and DRC rejection parameter q (Rpq, 0.75), the background signal was reduced by up to 100-fold at m/z 109 and the limit of quantitation (LOQ, 10σ) for ¹⁰⁹Ag was 0.5 ng g⁻¹. The proposed method was used to determine the concentration of Ag in twenty-eight soil standard reference materials (SRMs). The accuracy of the results suggests that the method has great potential for the direct determination of trace or ultra-trace levels of Ag in various environmental samples.
More Related Videos
04:48Setup of Capillary Electrophoresis-Inductively Coupled Plasma Mass Spectrometry (CE-ICP-MS) for Quantification of Iron Redox Species (Fe(II), Fe(III))
Published on: May 4, 2020
11:18A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)
Published on: July 11, 2017
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...