A collaborative effort to apply ergonomics to electric utility workers at generating stations
Amy Stone1, Richard Marklin, Patricia Seeley
1Department of Mechanical Engineering, Marquette University, Milwaukee, WI 53211, USA. amystone@wi.rr.com
Work (Reading, Mass.)
|June 16, 2011
Summary
Collaborative ergonomics teams identified and addressed musculoskeletal disorder risks in electric power plants. Interventions like optimized box heights and improved cart wheels reduced worker strain.
Area of Science:
- Occupational health
- Ergonomics
- Industrial engineering
Background:
- Musculoskeletal disorders (MSDs) pose significant risks to workers in fossil-fueled generating stations.
- A collaborative approach involving industry, academia, and research was needed to address these risks.
- Existing ergonomic assessments may not fully capture the complexities of utility work environments.
Purpose of the Study:
- To identify tasks with risk factors for MSDs among electricians, plant operators, and mechanics in generating stations.
- To propose and evaluate ergonomic interventions for identified high-risk tasks.
- To demonstrate the effectiveness of a collaborative ergonomics model in the electric power industry.
Main Methods:
- Assembled two ergonomics teams comprising skilled utility workers and trained ergonomists.
- Focused team efforts on specific worker groups: electricians and plant operators/mechanics.
- Conducted task analysis, including laboratory and field experiments, and anthropometric measurements.
Main Results:
- Recommended optimal electrical box heights based on anthropometric analysis.
- Demonstrated that low rolling resistance wheels significantly reduced the force needed to push carts.
- Showed that six-wheeled carts required less force to turn than four-wheeled carts.
Conclusions:
- A collaborative ergonomics approach is effective for identifying and mitigating MSD risks in the electric power industry.
- Developed practical interventions, such as optimized box heights and improved cart designs, to enhance worker safety.
- The collaborative model can be adapted by other industries to reduce the incidence, cost, and severity of workplace MSDs.
Related Concept Videos
Electrical Power
Electric power is the product of current and voltage, represented in units of joules per second, or watts. For example, cars often have one or more auxiliary power outlets with which you can charge a cell phone or other electronic devices. These outlets may be rated at 20 amps and 12 volts, so that the circuit can deliver a maximum power of 240 watts. Consider a 25 Watt bulb and a 60 Watt bulb. The conversion of electrical energy produces heat and light, while the kinetic energy lost by the...
Power System Distribution
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
Load-frequency control
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
Insulation Coordination
Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times for...
Induced Electric Fields: Applications
An important distinction exists between the electric field induced by a changing magnetic field and the electrostatic field produced by a fixed charge distribution. Specifically, the induced electric field is nonconservative because it does not work in moving a charge over a closed path. In contrast, the electrostatic field is conservative and does no net work over a closed path. Hence, electric potential can be associated with the electrostatic field but not the induced field. The following...
Generator Voltage Control
Generator voltage control is crucial for maintaining the stable operation of synchronous generators and wind turbines. In older models, a DC generator driven by the rotor delivers DC power to the rotor's field winding, and the power is transferred through slip rings and brushes. In the latest models, static or brushless exciters are used. Static exciters rectify AC power from the generator terminals and then transfer the DC power directly to the rotor. Brushless exciters, on the other hand, use...