Related Experiment Videos

A collaborative effort to apply ergonomics to electric utility workers at generating stations

Amy Stone1, Richard Marklin, Patricia Seeley

  • 1Department of Mechanical Engineering, Marquette University, Milwaukee, WI 53211, USA. amystone@wi.rr.com

Work (Reading, Mass.)
|June 16, 2011
PubMed
Summary

Collaborative ergonomics teams identified and addressed musculoskeletal disorder risks in electric power plants. Interventions like optimized box heights and improved cart wheels reduced worker strain.

Related Concept Videos

Electrical Power01:07

Electrical Power

Electric power is the product of current and voltage, represented in units of joules per second, or watts. For example, cars often have one or more auxiliary power outlets with which you can charge a cell phone or other electronic devices. These outlets may be rated at 20 amps and 12 volts, so that the circuit can deliver a maximum power of 240 watts. Consider a 25 Watt bulb and a 60 Watt bulb. The conversion of electrical energy produces heat and light, while the kinetic energy lost by the...
Power System Distribution01:25

Power System Distribution

Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
Load-frequency control01:28

Load-frequency control

Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
Insulation Coordination01:23

Insulation Coordination

Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times for...
Induced Electric Fields: Applications01:27

Induced Electric Fields: Applications

An important distinction exists between the electric field induced by a changing magnetic field and the electrostatic field produced by a fixed charge distribution. Specifically, the induced electric field is nonconservative because it does not work in moving a charge over a closed path. In contrast, the electrostatic field is conservative and does no net work over a closed path. Hence, electric potential can be associated with the electrostatic field but not the induced field. The following...
Generator Voltage Control01:21

Generator Voltage Control

Generator voltage control is crucial for maintaining the stable operation of synchronous generators and wind turbines. In older models, a DC generator driven by the rotor delivers DC power to the rotor's field winding, and the power is transferred through slip rings and brushes. In the latest models, static or brushless exciters are used. Static exciters rectify AC power from the generator terminals and then transfer the DC power directly to the rotor. Brushless exciters, on the other hand, use...