Related Experiment Video
Updated: Jun 1, 2026

Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Sources of thromboembolism in patients with correctly functioning mechanical valves: a single-center transesophageal
Marek Maciejewski1, Katarzyna Piestrzeniewicz, Ryszard Jaszewski
1Clinic of Cardiology, Institute of Cardiology and Cardiac Surgery, Medical University of Lodz, Poland.
Background:
In patients with mechanical prostheses (MP), thromboembolism is one of the most serious complications. The study aim was to assess the incidence of sources of thromboembolism in patients with correctly functioning MP with and without a history of thromboembolism.
Methods:
Two hundred ninety-seven patients with correctly functioning MP were enrolled in this single-center, transesophageal echocardiographic (TEE), retrospective, observational study. Two groups were analyzed: Group A, 183 patients with a history of thromboembolism, and Group B, 114 patients with no history of thromboembolism.
Results:
Definite sources of thromboembolism were revealed in 59% of patients in Group A, and sources of potential thromboembolism were revealed in 13% of patients in Group B (P < .001). Multiple sources of thromboembolism were present in 9% of patients in Group A and 1% of patients in Group B. Localization of sources of thromboembolism included MP ring (59% and 53% of patients in Groups A and B, respectively); left atrium/left atrium appendage (24%/21% and 13%/40% of patients in Groups A and B, respectively); and aorta (12% and 13% of patients in Groups A and B, respectively). Patients with multiple sources of thromboembolism were older (P < .001) and in a higher New York Heart Association (NYHA) class (P = .004). Patients with sources of thromboembolism in the aorta were older than the rest of the group (P < .01).
Conclusions:
In patients with correctly functioning MP, sources of thromboembolism are observed 4 times more often in case of the positive history of thromboembolism. The most common source of thromboembolism is thrombosis of MP ring. Age and heart failure predispose multiple sources of thromboembolism. One might consider control TEE after mechanical valve implantation, but only in selected group of patients without embolic events but with a higher risk of thromboembolism.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Mitral Valve Prolapse II: Assessment and Management
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
Aortic Regurgitation II: Clinical Features and Diagnostic Tests