Is mechanical ventilation associated with intraventricular hemorrhage in preterm infants?
Related Experiment Video
Updated: May 31, 2026

Modeling Posthemorrhagic Hydrocephalus of Prematurity in Rats
Published on: March 28, 2025
Hany Aly1, Tarek A Hammad, Jonah Essers
1Department of Newborn Services, The George Washington University and the Children's National Medical Center, Washington, DC, United States. haly@mfa.gwu.edu
Insights
Mechanical ventilation, especially in the delivery room, increases the risk of severe intraventricular hemorrhage (IVH) in very low birth weight (VLBW) infants. Avoiding early intubation significantly reduces the risk of severe IVH in these vulnerable newborns.
Area of Science:
- Neonatal Medicine
- Pediatric Critical Care
- Respiratory Physiology
Background:
- The impact of mechanical ventilation on intraventricular hemorrhage (IVH) in very low birth weight (VLBW) infants remains unclear due to routine ventilation practices.
- There is increasing interest in early nasal continuous positive airway pressure (ENCPAP) as an alternative to mechanical ventilation.
Purpose of the Study:
- To investigate the association between delivery room mechanical ventilation and severe IVH in VLBW infants.
- To evaluate respiratory management strategies using ENCPAP in two neonatal units.
Main Methods:
- A logistic regression model was used to analyze data from VLBW infants regarding delivery room intubation and mechanical ventilation within the first 3 days of life.
- Confounding variables including birth weight, gender, ventilation duration, and PCO2 levels were controlled for.
Main Results:
- Severe IVH occurred in 35 of 340 VLBW infants, with most receiving mechanical ventilation initiated in the delivery room or within the first 2 days.
- Lower birth weight, delivery room intubation, and longer duration of mechanical ventilation were independently associated with severe IVH.
- Delivery room intubation showed an adjusted odds ratio of 2.7 for severe IVH (CI: 1.1-6.6, P=0.03).
Conclusions:
- Mechanical ventilation is a significant predictor of severe IVH in VLBW infants.
- The timing of ventilation initiation and its duration are critical determinants of severe IVH.
- Infants not intubated in the delivery room or within the first 3 days have a minimal risk of severe IVH.
Background:
The impact of mechanical ventilation on the incidence of intraventricular hemorrhage (IVH) in very low birth weight (VLBW) infants is unknown, simply because the vast majority of these infants have been routinely intubated and mechanically ventilated. There is a growing interest in the use of early nasal continuous positive airway pressure (ENCPAP) and avoiding mechanical ventilation.
Objectives:
To examine the role of mechanical ventilation since delivery room in determining severe IVH in VLBW infants in two neonatal units that follow the same strategy of respiratory management using ENCPAP.
Methods:
We collected data on delivery room intubation and mechanical ventilation during the first 3 days of life in VLBW infants. Logistic regression model was constructed to test the relationship between early mechanical ventilation and the diagnosis of severe IVH after controlling for significant confounding variables, such as BW, gender, duration of mechanical ventilation, and partial pressure of CO(2) (PCO(2)).
Results:
Of the studied 340 VLBW, 35 infants had severe IVH; most of them received mechanical ventilation that started either in the delivery room (n=12) or during the first (n=10) and second (n=3) days of life. Severe IVH was independently associated with lower BW, mechanical ventilation in the delivery room, and the cumulative duration of mechanical ventilation during the first 3 days. The adjusted odds ratio for severe IVH in infants intubated in delivery room was (OR=2.7, CI: 1.1-6.6, P=0.03). Severe IVH was not associated with gender, prenatal steroids, early sepsis, or patent ductus arteriosus.
Conclusions:
Mechanical ventilation plays a role in predicting severe IVH. Both the time at which ventilation was initiated and the duration of ventilation are important determinants of severe IVH. Risk for severe IVH in infants who were never intubated in delivery room or during the first 3 days of life is miniscule.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Increased Intracranial Pressure ll: Pathophysiology
Increased Intracranial Pressure l: Introduction