Related Experiment Video
Updated: May 31, 2026

Exploring the Longissimus Muscle: Unraveling its Correlation with Meat Quality in Bos indicus and Crossbred Bulls
Published on: July 12, 2024
Development of a system for classification of pork loins for tenderness using visible and near-infrared reflectance
S D Shackelford1, D A King, T L Wheeler
1USDA-ARS, Roman L. Hruska US Meat Animal Research Center, Clay Center, NE 68933-0166, USA. steven.shackelford@ars.usda.gov
Abstract:
Boneless pork loins (n = 901) were evaluated either on the loin boning and trimming line of large-scale commercial plants (n = 465) or at the US Meat Animal Research Center abattoir (n = 436). Exposed LM on the ventral side of boneless loins was evaluated with visible and near-infrared spectroscopy (VISNIR; 450 to 1,000 nm) using a commercial system that was developed for on-line evaluation of beef tenderness. Boneless loin sections were aged (2°C) until 14 d postmortem, and two 2.54-cm-thick chops were obtained from the 11th-rib region. Fresh (never frozen) chops were cooked (71°C) and LM slice shear force (SSF) was measured on each of the 2 chops. Those 2 values were averaged, and that value was used for all analyses. Loins were blocked by plant (n = 3), production day (n = 24), and observed SSF (mean = 13.9 kg; SD = 3.7 kg; CV = 26.8%; range 6.4 to 32.4 kg). One-half of the loins were assigned to a calibration data set, which was used to develop regression equations, and one-half of the loins were assigned to a prediction data set, which was used to validate the regression equations. A partial least-squares regression model was developed, and loins were classified as predicted tender or not predicted tender if their VISNIR-predicted SSF was <14.0 kg or ≥14.0 kg, respectively. Analysis of variance was used to determine the effect of VISNIR classification on SSF. The calibration data set and prediction data set had 61.9 and 60.9% of the loins classified as predicted tender, respectively. For both the calibration data set and the prediction data set, mean SSF was less for loins predicted tender than loins not predicted tender (P < 0.001). Relative to loins that were not predicted tender, the percentage of loins with SSF ≥20 kg was less for loins predicted tender in the calibration data set (3.6 vs. 8.1%) and prediction data set (1.8 vs. 13.6%). These results clearly indicate that the VISNIR technology could be used to noninvasively classify pork loins on-line for tenderness.
More Related Videos
06:50O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Published on: November 8, 2019
10:25Construction of Models for Nondestructive Prediction of Ingredient Contents in Blueberries by Near-infrared Spectroscopy Based on HPLC Measurements
Published on: June 28, 2016
Related Concept Videos
Classification of Skeletal Muscle Fibers
Slow-Twitch Muscle Fibers
Slow oxidative, muscle fibers appear red due to large numbers of capillaries and high levels of...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...