Related Experiment Video
Updated: Aug 4, 2026

Collection and Extraction of Occupational Air Samples for Analysis of Fungal DNA
Published on: May 2, 2018
Collection of silica and asbestos aerosols by respirators at steady and cyclic flow
L M Brosseau1, M J Ellenbecker, J S Evans
1Harvard School of Public Health, Department of Environmental Science and Physiology, Boston, MA 02115.
Abstract:
Air purifying dust/mist respirators are presently tested using a silica aerosol under conditions of steady flow. In experiments, the predictive validity of such tests was evaluated by testing respirators using silica and asbestos aerosols under conditions of both steady and cyclic flow. Silica penetration at steady flow was reasonably predictive of silica penetration under cyclic flow. However, asbestos penetration under cyclic flow was not predicted well by penetration of either silica or asbestos at steady flow. Furthermore, the potential for exhalation valve failure under cyclic flow was identified. Current NIOSH protocols for evaluating respirator performance should be reconsidered in light of these findings.