Related Experiment Video
Updated: May 31, 2026

Ultrasonography of the Adult Male Urinary Tract for Urinary Functional Testing
Published on: August 14, 2019
Antegrade pressure measurement as a diagnostic tool in modern pediatric urology
Paul W Veenboer1, Tom P V M de Jong
1Pediatric Renal Center, Department of Pediatric Urology, University Children's Hospital, UMCU, P.O. Box 85090, 3508 AB, Utrecht, The Netherlands. p.w.veenboer@students.uu.nl
Introduction:
The antegrade pressure measurement (APM) or perfusion pressure-flow test (Whitaker test) is a method of antegrade measurement of pressure in the upper urinary tract. In this study, we present the long-term follow-up results of APMs performed in our institution in the late 1980s and early 1990s to see whether the diagnostic decisions that were based on the outcomes of the test prove to be correct in the long term.
Materials And Methods:
We conducted a retrospective study by searching our hospital's electronic database. We found a total of 16 APMs performed between 1987 and 1995 (10 boys, six girls; mean age 61 months).
Results:
In nine cases, action was undertaken immediately after the APM had been performed; in seven cases, this was a surgical procedure (re-implantation/re-calibration or pyeloplasty) after obstruction was demonstrated. In two cases (both postoperative after previous pyeloplasty), absence of obstruction was demonstrated and nephrostomy tubes were subsequently closed. In one case, this resulted in hydronephrosis that had to be treated with a new JJ stent. In all the seven cases in which no action was deemed necessary as a result of the outcome of the APM, long-term follow-up showed that intervention had indeed not been necessary.
Conclusion:
Although not often used anymore, the APM seems to be a safe and valuable diagnostic tool in the work up for possible urinary tract obstruction in children, especially in cases in which there is serious doubt concerning conservative watchful waiting.
Related Concept Videos
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Urodynamic Studies: Uroflowmetry
Nursing Assessment of the Genitourinary System III: Percussion and Auscultation
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Imaging Studies II: Ultrasonography
