Related Experiment Video
Updated: May 31, 2026

Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
Torsional profiles of new and used revo-s rotary instruments: an in vitro study
Bettina Basrani1, Karina Roth, Geoffrey Sas
1Discipline of Endodontics, University of Toronto, Toronto, Ontario, Canada. bettina.basrani@dentistry.utoronto.ca
Introduction:
This study investigated the torsional properties of new and used Revo-S Shaping Universal (SU) endodontic instruments.
Methods:
Torsional profiles were established following the American National Standards Institute/American Dental Association Specification No. 28. Unused SU instruments (group 1, control; n = 30) and instruments used in simulated root canals twice (group 2, n = 30) or six times (group 3, n = 30) were tested. Analysis of variance with the Bonferroni/Dunn post hoc test (α = 0.05) was used to analyze the torque and angle of rotation at fracture.
Results:
The maximum torque at fracture did not differ significantly among instruments in group 1 and groups 2 and 3. The angle of rotation at fracture decreased significantly (P < .01) from group 1 to groups 2 and 3.
Conclusions:
The repeated use of the SU rotary instruments significantly reduced the angle of rotation at fracture but did not reduce the torque at fracture.
Related Concept Videos
Residual Stresses in Circular Shafts
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Torsional Pendulum
As long as the rigid body's angular displacement is small, its oscillation can be modeled as a linear angular oscillation. The amplitude of the oscillation is an angle. The role of mass is played by the...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...