Evaluation of a microfabricated thermal modulator for comprehensive two-dimensional microscale gas chromatography
Sung-Jin Kim1, Gustavo Serrano, Kensall D Wise
1Center for Wireless Integrated Microsystems (WIMS), University of Michigan, Ann Arbor, Michigan 48109-2122, United States.
Abstract:
A microfabricated thermal modulator (μTM) designed for ultimate use in a comprehensive two-dimensional microscale gas chromatography (μGC × μGC) system is evaluated. The 2-stage device measures 13 mm (l) × 6 mm (w) × 0.5 mm (h) and consists of two interconnected serpentine etched-Si microchannels suspended from a thin Pyrex cap and wall-coated with PDMS (polydimethylsiloxane). The chip is mounted within a few tens of micrometers of a thermoelectric cooler that maintains both stages at a baseline temperature between -35 and -20 °C in order to focus analytes eluting from an upstream separation column. Each stage is heated to 210 °C sequentially at a rate as high as 2400 °C/s by independent thin-film resistors to inject the analytes in consecutive fractions to a downstream column, and then cooled at a rate as high as -168 °C/s. The average power dissipation is only ∼10 W for heating and 21 W for cooling without using consumable materials. In this study, the outlet of the μTM is connected directly to a flame ionization detector to assess its performance. Following a demonstration of basic operation, the modulated peak amplitude enhancement (PAE) and full-width-at-half-maximum (fwhm) are evaluated for members of a series of n-alkanes (C(6)-C(10)) as a function of the rim and stage temperatures; modulation period, phase, and offset; analyte concentration; and carrier-gas flow rate. A PAE as high as 50 and a fwhm as narrow as 90 ms are achieved for n-octane under optimized conditions.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
08:16Combustion Characterization and Model Fuel Development for Micro-tubular Flame-assisted Fuel Cells
Published on: October 2, 2016
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...