The use of a radiotelemetric ruminal bolus to detect body temperature changes in lactating dairy cattle
O Alzahal1, H Alzahal, M A Steele
1Department of Animal and Poultry Science, University of Guelph, Guelph, N1G 2W1, Canada.
Abstract:
The objective of this study was to validate the efficacy of a radiotelemetric bolus (RTB) to detect changes in ruminal temperature resulting from (1) systemic illnesses that are associated with febrile responses and (2) subacute ruminal acidosis (SARA). Eight rumen-fistulated, lactating Holstein cows (586±37 kg of body weight, 106±18 d in milk) were used in a replicated 4 × 4 Latin square design with a 2 × 2 factorial arrangement. Each period consisted of 21 d. The factors were 2 diets, a moderate forage:concentrate [MFC; 52:48; % of dry matter (DM)] or a high forage:concentrate (HFC; 65:35, % of DM) total mixed ration, and a challenge with a single intramammary injection of lipopolysaccharide (LPS; 100 μg derived from Escherichia coli 0111:B4) or no LPS (sterile saline). Thus, the 4 resulting treatments were (1) MFC with LPS challenge, (2) MFC with saline, (3) HFC with LPS challenge, and (4) HFC with saline. Cows were fed at 0800 and 1400 h daily. Cows received the intramammary injections at 0900 h of d 21. Ruminal pH and ruminal temperature were also measured on d 21 every minute via an indwelling logging system that resided in the ventral sac of the rumen and via a radiotelemetric bolus that resided in the reticulum. Vaginal temperature was also recorded every minute via temperature loggers. Prior to LPS injection, the duration of rumen pH below 5.6 (indicative of SARA) was higher in cows receiving MFC than cows receiving HFC (148±24 and 62±24 min/d, respectively). The temperature measured at the same time via RTB was higher for MFC than HFC cows (167±21 vs. 104 vs. 21 min/d above 38.8°C, respectively). The following day, cows challenged with LPS showed signs of mastitis within the injected quarters, depressed DM intake, decreased milk yield, and a peak vaginal temperature of 41.3±0.1°C 5.5h after the LPS injection. The RTB system successfully detected a fever response parallel to that measured by the vaginal loggers but temperature peak detected by RTB was, on average, 0.5°C lower than that detected by the vaginal logger. Although the RTB system was able to detect a temperature response to the diet effect before LPS challenge, it was unable to detect this effect during the LPS challenge, likely because cows receiving the LPS challenge had decreased feed consumption. In conclusion, radiotelemetry has the potential to improve the detection of SARA and fever on farm.
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...