A Methodological Approach to Non-invasive Assessments of Vascular Function and Morphology
Published on: February 7, 2015
Dynamic Doppler evaluation of the hand arteries to distinguish between primary and secondary raynaud phenomenon
Ugur Toprak1, Merve Hayretci, Zeynep Erhuner
1Department of Radiology, Ankara Numune Training and Research Hospital, Turkiye. toprakugur@yahoo.com
Objective:
The objective of our study was to use Doppler sonography to detect the flow characteristics and parameters of the hand arteries that are needed to distinguish between primary Raynaud phenomenon (RP) and secondary RP.
Subjects And Methods:
The diameter, resistive index (RI), and flow volume of the digital, ulnar, and radial arteries of patients with primary RP and those with secondary RP were measured at rest and after cold provocation. The flow starting time in the digital artery and the flow normalizing time of all three arteries were also recorded after cold provocation.
Results:
At baseline and after cold provocation, the diameters of the radial and digital arteries and the flow volumes of the three arteries were less in patients with secondary RP than in primary RP patients. In primary RP and secondary RP, the flow normalizing times (mean ± SD) were 9.8 ± 3.88 and 25.88 ± 7.14 minutes, respectively, in the radial artery; 11.3 ± 7.43 and 32.15 ± 12.57 minutes in the ulnar artery; and 12.22 ± 6.82 and 32.67 ± 10.76 minutes in the digital artery. A flow normalizing time cutoff in the radial artery of 17 minutes yielded a sensitivity of 90% and specificity of 100%. A flow normalizing time cutoff in the ulnar artery of 23 minutes yielded a sensitivity and specificity of 71% and 100%, respectively. A flow normalizing time cutoff in the digital artery of 23 minutes yielded a sensitivity and specificity of 82.6% and 98%, respectively. The flow starting time of the digital artery was 3.80 ± 3.27 minutes in primary RP and 16.78 ± 9.97 minutes in secondary RP (p < 0.0001). The flow starting time cutoff of the digital artery was 7 minutes (sensitivity, 82.6%; specificity, 95.7%).
Conclusion:
The diameter of the radial and distal arteries; flow volume; and flow volume normalizing time of the digital, ulnar, and radial arteries' flow starting time in the digital artery may be helpful in distinguishing between primary RP and secondary RP with high sensitivity and specificity values. These parameters may also facilitate objective follow-up of treatment. The noninvasive nature of Doppler sonography is an additional advantage, and there is no need for extra hardware or software.
More Related Videos
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Atherosclerosis II: Clinical Manifestations and Diagnostic Tests