Related Experiment Video
Updated: May 31, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Adrenal masses in patients with cancer: PET/CT characterization with combined CT histogram and standardized uptake
Marzio Perri1, Paola Erba, Duccio Volterrani
1Regional Center of Nuclear Medicine, University of Pisa Medical School, Italy. marzioperri@hotmail.com
Objective:
Our purpose was to determine the diagnostic performance of 18F-FDG PET/CT for characterizing adrenal masses in patients with cancer, combining standardized uptake value (SUV) and CT histogram analysis.
Materials And Methods:
A total of 117 adrenal masses in 93 patients with cancer (61 men and 32 women; mean [± SD] age, 67.2 ± 10.3 years; range, 38-84 years) were evaluated with FDG PET/CT. Of the 117 lesions, 42 were malignant according to histopathologic analysis or size change, whereas 75 were benign on the basis of stability for 6 months. Size, mean attenuation value, percentage of negative pixels at CT histogram analysis, maximum SUV (SUV(max)), and average SUV were calculated for each adrenal lesion. Moreover, FDG adrenal uptake was compared with radioactivity of the aorta, liver, and spleen by calculating the SUV ratios of adrenal lesion to aorta, adrenal lesion to liver, and adrenal lesion to spleen. PET/CT value was assessed by using independent t tests and receiving operating characteristic (ROC) analysis.
Results:
There was a statistically significant difference in size, attenuation value, percentage of negative pixels, and SUV between benign and malignant masses. All malignant lesions showed FDG activity higher than that in liver, spleen, and aorta, with SUV(max) greater than 2.8 in all cases, whereas with the CT histogram analysis, all lesions with a percentage of negative pixels higher than 10% were benign. Combined SUV and CT histogram analysis yielded 100% sensitivity, 97.3% specificity, 95.7% positive predictive value, and 100% negative predictive value. At ROC analysis, combined SUV and CT histogram analysis (area under the ROC curve [AUC], 0.996) was more accurate than simple SUV(max) analysis (AUC, 0.961) and the combination of SUV(max) and attenuation value (AUC, 0.987).
Conclusion:
The combination of SUV and CT histogram analysis allowed us to significantly improve the PET/CT diagnostic accuracy for characterizing adrenal lesions, leading to a significant reduction in the number of false-positive cases.
More Related Videos
07:54Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
10:04Analysis of 18FDG PET/CT Imaging as a Tool for Studying Mycobacterium tuberculosis Infection and Treatment in Non-human Primates
Published on: September 5, 2017
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...