Related Experiment Video
Updated: May 31, 2026

In utero Measurement of Heart Rate in Mouse by Noninvasive M-mode Echocardiography
Published on: November 22, 2013
Outcome of early first-trimester pregnancies (< 6.1 weeks) with slow embryonic heart rate
Elizabeth Kagan Arleo1, Robert N Troiano
1Weill Cornell Imaging, New York Presbyterian Hospital, NY 10065, USA. ekarleo@gmail.com
Objective:
The purpose of this article is to assess prospectively the value of concordant versus discordant gestational age (GA) calculations in predicting subsequent embryonic demise in embryos with a slow heart rate, as determined on early first-trimester ultrasound.
Subjects And Methods:
Thirty-six consecutive singleton pregnancies with slow embryonic heart rate (< 100 beats/min) measured on a 5.0- to 6.1-week ultrasound were prospectively identified. Pregnancies were defined as "discordant" if there was more than 5 days' difference between GA determined by biometrics compared with GA determined by last menstrual period and were defined as "concordant" if there was less than 5 days' difference between the GA measurements.
Results:
Of the 36 embryos with heart rate less than 100 beats/min at 5.0-6.1 weeks' GA, 16 went on to demise and 20 survived. Of the 16 that went on to demise, 14 were discordant (88%) and two were concordant (12%). Of the 20 that survived, 16 were concordant (80%) and four were discordant (20%). The proportion of discordant pregnancies that went on to demise was 14 of 18 (negative predictive value, 78%). The proportion of concordant pregnancies that went on to survival was 16 of 18 (positive predictive value, 89%). The rate of demise in the discordant group was significantly higher than that in the concordant group (p < 0.001, Fisher's exact test).
Conclusion:
Embryonic heart rate less than 100 beats/min detected at 6.1 weeks or less is not necessarily a poor prognostic indicator. The likelihood of subsequent first-trimester survival is significantly higher if there is concordance between GA as calculated by biometrics and last menstrual period than if there is discordance.
Related Concept Videos
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Development of the Heart
As the embryo undergoes lateral folding, these paired tubes approach each other, merging into a single primitive heart tube by...
Dysrhythmias III: Characteristics of Dysrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Decreased pulse rate
There are specific risk factors that can elevate the likelihood of developing bradycardia. Advanced age is a significant factor, with bradycardia...

