Related Experiment Video
Updated: May 31, 2026

Three-Dimensionally Printed Microfluidic Cross-flow System for Ultrafiltration/Nanofiltration Membrane Performance Testing
Published on: February 13, 2016
Drug retention by inline filters--effect of positively charged polyethersulfone filter membranes on drug solutions
Joanna Gasch1, Claudia S Leopold, Holger Knoth
1Klinik-Apotheke, Universitätsklinikum Carl Gustav Carus der Technischen Universität Dresden, Fetscherstrasse 74, Dresden, Germany. joanna@hw-arts.de
Objective:
The use of infusion filters in pediatrics is controversially discussed. Their application is an excellent opportunity to prevent complications, but there are researchers, who do not see any advantage in using inline filters. This paper describes the interaction of five different drugs with a positively charged as opposed to an uncharged polyethersulfone (PES(+) versus PES(0)) membrane.
Methods:
To measure the extent and the mechanism of interaction, PES(+) versus PES(0) membranes and furosemide sodium, potassium canrenoate, digitoxin, digoxin and adenosine, each 30μmol/l, were investigated. Salt ions with different hydrodynamic radii and different concentrations have been used in the eluents.
Results:
During furosemide sodium and potassium canrenoate filtration with PES(+), the onset of UV absorption depends on the electrolyte concentration in the eluent: the lower the electrolyte concentration the later the onset of UV absorption. A correlation between the hydrodynamic volume of the different salt ions used and the onset of UV absorption could be proven for both substances: The larger the hydrodynamic volume of the extrinsic ion, the later the onset of the UV absorption if the same electrolyte concentration was used. Due to a higher structural density of PES(+) than PES(0) a delayed onset of UV absorption during filtration of digitoxin and digoxin with the PES(+) membrane could be observed. No correlation between the hydrodynamic volume of the different salt ions used and the onset of UV absorption could be seen. With adenosine neither the filter type nor the electrolyte concentration or the hydrodynamic volume of the salt ions had an influence on the onset time of absorption.
Conclusion:
The results obtained with the anionic drugs investigated are particularly relevant if low drug concentrations in a saltless infusion solution are applied in combination with a charged filter membrane. Therefore, for each infusion formulation, a careful selection of the filter material is essential.
More Related Videos
10:32On-chip Isotachophoresis for Separation of Ions and Purification of Nucleic Acids
Published on: March 2, 2012
12:11A Modified EPA Method 1623 that Uses Tangential Flow Hollow-fiber Ultrafiltration and Heat Dissociation Steps to Detect Waterborne Cryptosporidium and Giardia spp.
Published on: July 9, 2012
Related Concept Videos
Dialysis
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration
Drug Elimination by Renal Route: Tubular Reabsorption
Drug Elimination by Renal Route: Tubular Secretion
Pore Transport and Ion-Pair Transport
Pore transport, also known as convective transport, is a process where small molecules like urea, water, and sugars rapidly cross cell membranes as though there were channels or pores in the membrane. Although direct microscopic evidence is limited but the concept of pores or channels is widely accepted based on physiological evidence. Despite the lack of direct microscopic...
Renal Drug Excretion: Tubular Reabsorption