Related Experiment Video
Updated: May 31, 2026

Translaminar Autonomous System Model for the Modulation of Intraocular and Intracranial Pressure in Human Donor Posterior Segments
Published on: April 24, 2020
Measurement of intraocular and intracranial pressure: is there a relationship?
Tyler Kirk1, Keith Jones, Spencer Miller
1Department of Ophthalmology, University of Mississippi Medical Center, Jackson, MS 39216, USA. tkirk@umc.edu
Objective:
To study whether noninvasive, intraocular pressure (IOP) measurements significantly correlate with standard intracranial pressure (ICP) measurements.
Methods:
This prospective, blinded study enrolled 46 patients who were undergoing medically indicated lumbar puncture (LP). IOP was measured by applanation tonometry immediately prior to measuring LP opening pressure. One patient was excluded due to unsuccessful ICP measurement.
Results:
In the 45 patients to successfully undergo IOP and ICP measurement, there was no significant relationship between ICP and average IOP for both eyes (r = -0.005). There was no significant relationship between ICP and IOP in either eye, when studied individually(r = 0.03 ocular dexter [OD], r = -0.05 ocular sinister [OS]). There was no significant relationship between ICP and IOP when the eye best correlated to the patient's ICP was chosen (r = -0.01).
Interpretation:
No significant relationship between ICP and IOP was observed. Noninvasive IOP measurements do not predict ICP.
Related Concept Videos
Increased Intracranial Pressure l: Introduction
Increased Intracranial Pressure ll: Pathophysiology
Glaucoma: Overview
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...