Background:
ECG -gated myocardial perfusion imaging is a sensitive test for diagnosis of ischemia as well as scarred myocardium. It provides additional information on global and regional myocardial contractile function. A number of methods are available to calculate left ventricular volumes and ejection fractions, which depends on various technical and patients specific factor.
Objective:
This study was carried out to measure effect of reconstruction filter in calculations of left ventricularend diastolic volume (EDV) and end systolic volume (ESV) and left ventricular ejection fraction (LVEF) from 99mTc-sestamibi myocardial perfusion imaging.
Materials And Methods:
99mTc-sestamibi-gated SPECT myocardial perfusion imaging was performed in 90 patients. Studies were reconstructed with Butterworth and Metz filters.
Results:
Mean ejection fraction with Butterworth and Metz filter are 64.3 and 64.2, respectively. Mean EDV is for Butterworth and Metz filters are 77.3 and 78.5 ml, respectively. While ESV was 36.49 and 36.63 ml, stroke volume calculated was 41.54 and 42 ml for Butterworth and Metz filters, respectively. Pearsons's correlation coefficients between results calculated with Metz and Butterworth filters were 0.994 for ESV, 0.996 for EDV, 0.966 for LVEF and 0.925 for SV. Student 't' test was applied on the data and no significant difference was noted between parameter estimated by Butterworth or Metz filter.
Conclusion:
This study shows that difference of filter application has no significant effect in computing left ventricular function parameters.
More Related Videos
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
05:32Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
Published on: February 21, 2025
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...