Related Experiment Video
Updated: May 31, 2026

Disposable Dosators for Pulmonary Insufflation of Therapeutic Agents to Small Animals
Published on: March 30, 2017
A method for the aerodynamic design of dry powder inhalers
O Ertunç1, C Köksoy, H Wachtel
1Friedrich-Alexander-University Erlangen-Nuremberg Cauerstrasse 4, D-91058 Erlangen, Germany. ertunc@lstm.uni-erlangen.de
Abstract:
An inhaler design methodology was developed and then used to design a new dry powder inhaler (DPI) which aimed to fulfill two main performance requirements. The first requirement was that the patient should be able to completely empty the dry powder from the blister in which it is stored by inspiratory effort alone. The second requirement was that the flow resistance of the inhaler should be geared to optimum patient comfort. The emptying of a blister is a two-phase flow problem, whilst the adjustment of the flow resistance is an aerodynamic design problem. The core of the method comprised visualization of fluid and particle flow in upscaled prototypes operated in water. The prototypes and particles were upscaled so that dynamic similarity conditions were approximated as closely as possible. The initial step in the design method was to characterize different blister prototypes by measurements of their flow resistance and particle emptying performance. The blisters were then compared with regard to their aerodynamic performance and their ease of production. Following selection of candidate blisters, the other components such as needle, bypass and mouthpiece were dimensioned on the basis of node-loop operations and validation experiments. The final shape of the inhaler was achieved by experimental iteration.
Related Concept Videos
Inhaled Medications
Asthma-IV: Diagnostic and Management
Clinical Assessment for Asthma:
This is the first step in diagnosing and managing asthma. It includes:
Design Example: Flow Through a Fire Extinguisher
The key to understanding how the...
Additional Routes of Drug Administration
Administering drugs via inhalation allows for the direct delivery of gaseous, volatile substances or droplets to different parts of the respiratory tract. One of the advantages of the inhalation route is the rapid absorption of drugs into the circulatory system, which is possible because of the large surface area of...
Bernoulli's Principle: Applications