Assessment of Child Anthropometry in a Large Epidemiologic Study
Published on: February 2, 2017
Body-density measurement in children: the BOD POD versus Hydrodensitometry
Jason C Holmes1, Ann L Gibson, J Gualberto Cremades
1Dept. of Sport and Exercise Science, Barry University, Miami Shores, FL, USA.
Objective:
To compare estimates of body density (Db) from air-displacement plethysmography (ADP) with measured and predicted thoracic-gas-volume (TGV) measurements and those from hydrodensitometry (HD) in children.
Methods:
Seventeen participants (13 male and 4 female; 10.1 ± 2.20 yr, 42.0 ± 15.03 kg, 145.6 ± 17.41 cm, 30.0 ± 8.66 kg/m²) were tested using ADP and HD, with ADP always preceding HD. Db estimates were compared between ADP with measured TGV, ADP with predicted TGV, and the reference measure, HD. Regression analyses were used to assess the accuracy of the ADP methods, and potential bias between the ADP procedures and HD were evaluated using Bland-Altman analyses. The cross-validation criteria described by Lohman for estimating Db relative to HD were used to interpret the results of the study.
Results:
A significant difference was found between Db estimates from ADP with measured TGV (1.0453 ± 0.01934 g/cm³) and ADP with predicted TGV (1.0415 ± 0.01858 g/cm³); however, neither was significantly different from Db obtained by the reference HD procedure (1.0417 ± 0.02391 g/cm³). For both ADP procedures, regression analyses produced an r = .737-.738, r² = .543-.544, and SEE = 0.02 g/cm³, and the regression lines deviated significantly from the line of identity; however, no significant biases were indicated.
Conclusions:
Despite no significant mean differences between Db estimates from the ADP procedures and HD, more cross-validation research is needed before recommending the BOD POD for routine use with children in clinical and research settings.
Related Concept Videos
Body Water Content and Fluid Compartments
Density
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Drug Dosing: Infants and Children
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: