Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A new single-antigen serological test accurately detects horses infected with Streptococcus equi subsp equi.

Journal of the American Veterinary Medical Association·2026
Same author

Distinct Plasmodium falciparum Erythrocyte Membrane Protein 1 Domain Cassette-Associated Antibody Gaps Specific to Cerebral Malaria and Severe Malarial Anemia.

The Journal of infectious diseases·2026
Same author

Multicenter Clinical Comparison of the 10-Minute AMDI Fast PCR Mini Respiratory Panel and the Cepheid Xpert Xpress CoV-2/Flu/RSV plus.

The Journal of molecular diagnostics : JMD·2026
Same author

Scalable Ni-Based Diffusion Synthesis of Highly Graphitic Nanointerlaced and Photopatternable Material with Fast Charge Transfer Kinetics.

Langmuir : the ACS journal of surfaces and colloids·2026
Same author

Infants under 24 months with severe malaria have a serological profile of active infection with Epstein Barr Virus.

The Journal of infectious diseases·2026
Same author

Analytical performance of the AMDI™ Fast PCR Mini Respiratory Panel.

Diagnostic microbiology and infectious disease·2026

Related Experiment Video

Updated: May 31, 2026

Computer Numerical Control Micromilling of a Microfluidic Acrylic Device with a Staggered Restriction for Magnetic Nanoparticle-Based Immunoassays
09:58

Computer Numerical Control Micromilling of a Microfluidic Acrylic Device with a Staggered Restriction for Magnetic Nanoparticle-Based Immunoassays

Published on: June 23, 2022

A multiplexed immunoassay system based upon reciprocating centrifugal microfluidics.

Zahra Noroozi1, Horacio Kido, Régis Peytavi

  • 1Department of Mechanical and Aerospace Engineering, University of California, Irvine, 4200 Engineering Gateway, Irvine, California 92697-3975, USA.

The Review of Scientific Instruments
|July 5, 2011
PubMed
Summary
This summary is machine-generated.

A new microfluidic disk system enhances immunoassay processing. This centrifugal disk-based micro-total analysis system (μTAS) significantly reduces assay time and reagent use through an innovative fluidic reciprocating mechanism.

More Related Videos

Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles
11:54

Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles

Published on: March 13, 2017

Electrowetting-based Digital Microfluidics Platform for Automated Enzyme-linked Immunosorbent Assay
08:22

Electrowetting-based Digital Microfluidics Platform for Automated Enzyme-linked Immunosorbent Assay

Published on: February 23, 2020

Related Experiment Videos

Last Updated: May 31, 2026

Computer Numerical Control Micromilling of a Microfluidic Acrylic Device with a Staggered Restriction for Magnetic Nanoparticle-Based Immunoassays
09:58

Computer Numerical Control Micromilling of a Microfluidic Acrylic Device with a Staggered Restriction for Magnetic Nanoparticle-Based Immunoassays

Published on: June 23, 2022

Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles
11:54

Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles

Published on: March 13, 2017

Electrowetting-based Digital Microfluidics Platform for Automated Enzyme-linked Immunosorbent Assay
08:22

Electrowetting-based Digital Microfluidics Platform for Automated Enzyme-linked Immunosorbent Assay

Published on: February 23, 2020

Area of Science:

  • Biomedical Engineering
  • Analytical Chemistry
  • Microfluidics

Background:

  • Semi-automated immunoassays are crucial for diagnostics.
  • Current high-throughput systems face challenges in efficiency and cost.
  • Microfluidic systems offer potential for miniaturization and automation.

Purpose of the Study:

  • To develop a novel, cost-effective, high-throughput micro-total analysis system (μTAS) for immunoassays.
  • To introduce an innovative fluidic design for enhanced micro-mixing and assay efficiency.
  • To reduce processing time and reagent consumption in immunoassay development.

Main Methods:

  • Development of a centrifugal disk-based microfluidic platform.
  • Implementation of a reciprocating fluidic mechanism utilizing centrifugal acceleration and pneumatic energy.
  • Design of a disposable immunoassay disk with specialized fluidic structures.
  • Optimization of alternating high and low centrifugal acceleration for reciprocating flow.

Main Results:

  • Achieved very efficient micro-mixing through the reciprocating fluidic mechanism.
  • Maximized incubation/hybridization efficiency between antibodies and antigens.
  • Reduced immunoassay processing time by one order of magnitude.
  • Reduced reagent consumption by one order of magnitude.

Conclusions:

  • The developed centrifugal disk-based μTAS offers a low-cost, high-throughput solution for semi-automated immunoassays.
  • The novel reciprocating fluidic mechanism significantly enhances assay efficiency and reduces resource utilization.
  • This technology has the potential to improve the speed and economics of immunoassay development and application.