Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Atomic Emission Spectroscopy: Overview01:20

Atomic Emission Spectroscopy: Overview

Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle01:19

Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle

Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Emission Spectroscopy: Instrumentation01:22

Atomic Emission Spectroscopy: Instrumentation

The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers.  Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview01:19

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then passed on to...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Systematic review of camellia oil: from preparation, quality control, bioactive substances, authenticity identification to comprehensive application.

Food chemistry·2026
Same author

Advances in Camellia oleifera seed meal Saponins: Extraction, analysis, bioactivity, and application.

Food chemistry·2025
Same author

Experimental investigation of second-harmonic emission pattern from dual-laser-induced air plasma.

Optics letters·2025
Same author

Systematic review of hypoglycemic polysaccharides: sources, preparation, and identification techniques, evaluation models, structure-activity relationships, and mechanistic insights.

Critical reviews in food science and nutrition·2025
Same author

Coherent detection of pulsed terahertz waves in solid, gaseous, and liquid media.

Fundamental research·2025
Same author

Screening study of hydroxytyrosol metabolites from in vitro fecal fermentation and their interaction with intestinal barrier repair receptor AhR.

Journal of food science·2024

Related Experiment Video

Updated: May 31, 2026

Non-equilibrium Microwave Plasma for Efficient High Temperature Chemistry
07:17

Non-equilibrium Microwave Plasma for Efficient High Temperature Chemistry

Published on: August 1, 2017

"All air-plasma" terahertz spectroscopy.

Benjamin Clough1, Jingle Liu, X-C Zhang

  • 1Center for Terahertz Research, Rensselaer Polytechnic Institute, Troy, New York 12180, USA.

Optics Letters
|July 5, 2011
PubMed
Summary
This summary is machine-generated.

Researchers developed an "all air-plasma" terahertz system for detecting explosive signatures up to 6 THz. This novel method bypasses limitations of traditional terahertz spectroscopy, enabling remote sensing applications.

More Related Videos

Terahertz Microfluidic Sensing Using a Parallel-plate Waveguide Sensor
07:28

Terahertz Microfluidic Sensing Using a Parallel-plate Waveguide Sensor

Published on: August 30, 2012

Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown
09:40

Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown

Published on: February 14, 2014

Related Experiment Videos

Last Updated: May 31, 2026

Non-equilibrium Microwave Plasma for Efficient High Temperature Chemistry
07:17

Non-equilibrium Microwave Plasma for Efficient High Temperature Chemistry

Published on: August 1, 2017

Terahertz Microfluidic Sensing Using a Parallel-plate Waveguide Sensor
07:28

Terahertz Microfluidic Sensing Using a Parallel-plate Waveguide Sensor

Published on: August 30, 2012

Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown
09:40

Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown

Published on: February 14, 2014

Area of Science:

  • Optics and Photonics
  • Spectroscopy
  • Plasma Physics

Background:

  • Terahertz (THz) spectroscopy is a powerful tool for material analysis.
  • Traditional THz systems face limitations including water vapor absorption, phonon resonance, and directional signal collection.
  • Solid-state materials and biased electrodes are often required for THz generation and detection.

Purpose of the Study:

  • To demonstrate a novel terahertz wave generation and detection system.
  • To overcome the limitations of conventional THz spectroscopy.
  • To enable remote sensing of explosive material signatures.

Main Methods:

  • Utilizing an "all air-plasma" terahertz system.
  • Generating and detecting terahertz waves up to 6 THz.
  • Encoding explosive material resonant signatures into the 357 nm nitrogen fluorescence line of a bichromatic field-induced laser plasma filament.

Main Results:

  • Successful terahertz wave generation and detection up to 6 THz were achieved.
  • The system operates without solid-state materials or biased electrodes.
  • Explosive material resonant signatures were successfully encoded and detected.

Conclusions:

  • The "all air-plasma" terahertz system offers a practical solution for THz spectroscopy.
  • This technology can be extended to remote locations, overcoming environmental and directional limitations.