Comparative study of 2-hydroxy propyl beta cyclodextrin and calixarene as ionophores in potentiometric ion-selective electrodes for neostigmine bromide
Related Experiment Video
Updated: May 31, 2026

A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Amira M El-Kosasy1, Marianne Nebsen, Mohamed K Abd El-Rahman
1Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University, Abbassia, 11566 Cairo, Egypt.
Abstract:
Three novel neostigmine bromide (NEO) selective electrodes were investigated with 2-nitrophenyl octyl ether as a plasticiser in a polymeric matrix of polyvinyl chloride (PVC). Sensor 1 was fabricated using tetrakis(4-chlorophenyl)borate (TpClPB) as an anionic exchanger without incorporation of an ionophore. Sensor 2 used 2-hydroxy propyl β-cyclodextrin as an ionophore while sensor 3 was constructed using 4-sulfocalix-8-arene as an ionophore. Linear responses of NEO within the concentration ranges of 10(-5) to 10(-2), 10(-6) to 10(-2) and 10(-7) to 10(-2) mol L(-1) were obtained using sensors 1, 2 and 3, respectively. Nernstian slopes of 51.6 ± 0.8, 52.9 ± 0.6 and 58.6 ± 0.4 mV/decade over the pH range of 4-9 were observed. The selectivity coefficients of the developed sensors indicated excellent selectivity for NEO. The utility of 2-hydroxy propyl β-cyclodextrin and 4-sulfocalix[8]arene as ionophores had a significant influence on increasing the membrane sensitivity and selectivity of sensors 2 and 3 compared to sensor 1. The proposed sensors displayed useful analytical characteristics for the determination of NEO in bulk powder, different pharmaceutical formulations, and biological fluids (plasma and cerebrospinal fluid (CSF)) and in the presence of its degradation product (3-hydroxyphenyltrimethyl ammonium bromide) and thus could be used for stability-indicating methods.
More Related Videos
11:08Double-barreled and Concentric Microelectrodes for Measurement of Extracellular Ion Signals in Brain Tissue
Published on: September 5, 2015
06:59A Fluorescence-Based Assay of Membrane Potential for High-Throughput Functional Study of Two Endogenous Ion Channels in Two Epithelial Cell Lines
Published on: June 22, 2022
Related Concept Videos
Potentiometry: Membrane Electrodes
Ion-Exchange Chromatography
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential ensures...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Ion Exchange
Titration of Polyprotic Base with a Strong Acid