Related Experiment Video
Updated: May 31, 2026

Normothermic Negative Pressure Ventilation Ex Situ Lung Perfusion: Evaluation of Lung Function and Metabolism
Published on: February 14, 2022
Natural-orifice transluminal endoscopic surgery: low-pressure pneumoperitoneum is sufficient and is associated with
S von Delius1, A Schorn, M Grimm
1II. Medizinische Klinik, Klinikum rechts der Isar der Technischen Universität München, Ismaninger Strasse 22, Munich, Germany. stefan_ruckert@yahoo.de
Background And Aims:
The aim of this randomized trial in the acute porcine model was to compare the quality of transgastric peritoneoscopy with the use of low-pressure versus standard-pressure pneumoperitoneum and to evaluate the respective associated cardiopulmonary changes.
Methods:
For transgastric peritoneoscopy, carbon dioxide was insufflated via the endoscope for a constant intraperitoneal pressure of 6 mmHg or 12 mmHg in 9 pigs each. The quality of transgastric peritoneoscopy was rated on a visual analog scale (0 mm, min.; 100 mm, max.) by the endoscopist, who was blinded to the intraperitoneal pressure. The cardiac index and global end-diastolic volume index (GEDVI, reflecting preload) were measured every 3 minutes by transpulmonary thermodilution. The following were also recorded: heart rate, mean arterial pressure (MAP), systemic vascular resistance index (SVRI, reflecting afterload), peak inspiratory pressure (PIP), pH, PCO (2), and PO (2).
Results:
The quality of transgastric peritoneoscopy with the use of low-pressure pneumoperitoneum was not inferior to that obtained using standard-pressure pneumoperitoneum (87.0 mm vs. 87.3 mm; P<0.05). In both groups we observed a statistically significant rise in MAP and SVRI. The increase in SVRI was less pronounced during low-pressure peritoneum ( P=0.042), indicating a reduced stress response in comparison to standard-pressure peritoneum. There were no relevant differences between the groups in relation to cardiac index, GEDVI, and heart rate. An intra-abdominal pressure of 6 mmHg also led to better oxygenation ( P=0.031 for difference in PO (2) between the two groups) due to lower peak inspiratory pressure ( P<0.001 for difference). There were only slight differences between the groups with regard to pH and PCO (2).
Conclusions:
Pneumoperitoneum of 12-16 mmHg is used for standard laparoscopy. For NOTES, low-pressure pneumoperitoneum is sufficient and is associated with an improved cardiopulmonary response compared to standard-pressure pneumoperitoneum.
Related Concept Videos
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
