A Protocol for Comprehensive Assessment of Bulbar Dysfunction in Amyotrophic Lateral Sclerosis (ALS)
Published on: February 21, 2011
UES pressure during phonation using high-resolution manometry and 24-h dual-probe pH-metry in patients with muscle
Evelyne Van Houtte1, Kristiane Van Lierde, Evelien D'haeseleer
1Department of Otolaryngology, University Hospital Ghent, Ghent, Belgium. Evelyne.vanhoutte@ugent.be
Abstract:
Muscle tension dysphonia (MTD) is the pathological condition in which excessive tension of the (para)laryngeal musculature leads to a disturbed voice. This study was developed to investigate if differences in pressure in the upper esophageal sphincter (UES) were present in patients with MTD in comparison with normal speakers. Concurrently, all patients were screened for gastroesophageal reflux disease (GERD) as an associated cause or aggravating factor in MTD. The study's design was a prospective case-control study. Fourteen patients with MTD (mean age = 40.2 years, range = 22-62 years) and 14 adult controls (mean age = 33.9 years, range = 23-58 years) were studied. A water-perfusion assembly with 22 sensors was positioned to record pressures during phonation. The mean values of the phonation pressures at the UES were measured. All patients underwent a dual-probe 24-h ambulatory pH impedance in order to measure the pH and the height of the refluxes from the lower esophageal sphincter to the hypopharynx. There were no significant differences in the UES pressures of patients with MTD compared to those of normal speakers during phonation tasks and reading. Two patients were identified with GERD. In these patients the refluxate reached the UES but this did not influence the UES pressures. We conclude that this study was not able to detect differences in phonation-induced UES pressures between patients with MTD and normal speakers using a standard water-perfusion high-resolution manometry assembly. Future investigation should be focused on developing probes with closely spaced sensors in the hypopharynx and the esophagus in order to investigate if differences in UES pressures in these study populations are present.
Related Concept Videos
Physical Assessment of the Respiratory Tract III: Percussion
Percussion in Respiratory Assessment
Percussion evaluates underlying tissue composition with audible and tactile vibrations,...
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.