Related Experiment Video
Updated: May 31, 2026

Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
Published on: February 18, 2020
A novel mother and child technique with a 4F inner catheter based on proper alignment of both catheters
Takashi Ashikaga1, Kaoru Sakurai, Yasuhiro Satoh
1Department of Cardiology, National Hospital Organization, Disaster Medical Center, Tokyo, Japan. ashikaga-ind@umin.ac.jp
We occasionally encounter difficult cases of stent and balloon delivery to the distal lesion due to severe calcification or tortuosity of the proximal section. We describe a novel mother and child technique with a 4F inner catheter based on proper alignment of both catheters to deliver balloon, stent, and guide catheter to the distal lesion.
We occasionally encounter difficult cases of stent and balloon delivery to the distal lesion due to severe calcification or tortuosity of the proximal section. We describe a novel mother and child technique with a 4F inner catheter based on proper alignment of both catheters to deliver balloon, stent, and guide catheter to the distal lesion.
More Related Videos
Related Concept Videos
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization IV: Nursing Management