Updated: May 31, 2026

Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities
06:51

Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities

Published on: February 20, 2021

Postal dosimetry audit test for small photon beams.

María del Mar Espinosa1, Luis Núñez, José Luis Muñiz

  • 1Hospital Universitario Puerta de Hierro Majadahonda, Madrid, Spain.

Radiotherapy and Oncology : Journal of the European Society for Therapeutic Radiology and Oncology
|July 9, 2011
PubMed
Summary

A new postal audit using Thermoluminescent Dosimeters (TLD) effectively verifies absorbed doses in small photon beams used in Intensity Modulated Radiotherapy (IMRT) and Stereotactic Radiosurgery (SRS). This method ensures accurate dose delivery for advanced radiation therapy techniques.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Correction: Weight-related changes in MRI-derived measures of body composition and liver steatosis: a large-scale analysis for obesity trial design.

International journal of obesity (2005)·2026
Same author

Epidemiological and Clinical Characterization of Atopic Dermatitis in Dogs from Quito, Ecuador: Retrospective Analysis of Cases (2018-2025).

Veterinary sciences·2026
Same author

First Molecular Evidence of the Presence of Avian Astroviruses in Turkey Flocks of Ecuador Through the Standardization of RT-qPCR Assays Based on SYBR Green.

Viruses·2026
Same author

Weight-related changes in MRI-derived measures of body composition and liver steatosis: a large-scale analysis for obesity trial design.

International journal of obesity (2005)·2026
Same author

<i>mecA</i> and <i>mecC</i> Positive Strains of <i>Staphylococcus aureus</i> Detected and Isolated from Raw Milk of Ecuador.

Antibiotics (Basel, Switzerland)·2025
Same author

Quality and antibiotic residues in raw milk sold informally in Manabí and Santo Domingo de los Tsáchilas, Ecuador.

Italian journal of food safety·2025

Area of Science:

  • Medical Physics
  • Radiation Oncology
  • Dosimetry

Background:

  • Advanced radiotherapy techniques like IMRT and SRS increasingly utilize small radiation beams (<4 cm).
  • Accurate dose measurement in small beams presents unique challenges compared to larger beams.
  • Quality assurance for small beam dosimetry is critical for patient safety and treatment efficacy.

Purpose of the Study:

  • To develop and validate a postal audit system for checking absorbed doses in small photon beams.
  • To assess the accuracy and suitability of Thermoluminescent Dosimeters (TLD) for this purpose.
  • To ensure reliable dose verification in clinical settings employing advanced radiotherapy.

Main Methods:

  • A postal audit system using small TLD-100 chips (1x1x1 mm³) within a PMMA phantom was designed.

More Related Videos

Irradiator Commissioning and Dosimetry for Assessment of LQ &alpha; and &beta; Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
06:20

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition

Published on: March 11, 2021

Effective Analysis of Human Exposure Conditions with Body-worn Dosimeters in the 2.4 GHz Band
06:43

Effective Analysis of Human Exposure Conditions with Body-worn Dosimeters in the 2.4 GHz Band

Published on: May 2, 2018

Related Experiment Videos

Last Updated: May 31, 2026

Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities
06:51

Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities

Published on: February 20, 2021

Irradiator Commissioning and Dosimetry for Assessment of LQ &alpha; and &beta; Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
06:20

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition

Published on: March 11, 2021

Effective Analysis of Human Exposure Conditions with Body-worn Dosimeters in the 2.4 GHz Band
06:43

Effective Analysis of Human Exposure Conditions with Body-worn Dosimeters in the 2.4 GHz Band

Published on: May 2, 2018

  • The system was mailed to 14 centers for irradiation with 1 cm and 3 cm side/diameter beams at a prescribed dose of 1.5 Gy at 10 cm depth.
  • System properties were validated through experimental measurements and Monte Carlo simulations prior to the audit.
  • Main Results:

    • The audit achieved dose deviations below 5% in 69% of centers for 1x1 cm² beams and 64% for 3x3 cm² beams.
    • Investigated deviations exceeding 5% led to necessary corrections, improving overall accuracy.
    • The system demonstrated a high level of agreement between prescribed and measured doses.

    Conclusions:

    • The developed TLD postal audit system is suitable for verifying absorbed doses in small photon beams.
    • The audit provides accurate dose verification with an overall accuracy of 2.9% (1 s).
    • This method enhances quality assurance for advanced radiation therapy techniques involving small beams.