Related Experiment Video
Updated: May 31, 2026

10:28
Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization
Published on: July 5, 2016
Digital in-line X-ray holography with zone plates
1Angewandte Physikalische Chemie, Universität Heidelberg, Im Neuenheimer Feld 253, D-69120 Heidelberg, Germany.
Ultramicroscopy
|July 12, 2011
Summary
Zone plates create bright X-ray point sources for digital holography, enabling faster, high-resolution imaging of biological samples with reduced radiation damage. This advances X-ray microscopy techniques.
Area of Science:
- Optics and Photonics
- X-ray Microscopy
- Biophysics
Background:
- Free-electron laser (FEL) sources offer potential for damage-free, high-resolution X-ray microscopy.
- Digital in-line holography is a coherent imaging technique requiring high-flux X-ray point sources.
- Conventional methods using pinholes are limited by long exposure times.
Purpose of the Study:
- To investigate the use of zone plates for generating X-ray point sources.
- To apply these sources for holographic microscopy of biological specimens.
- To assess the efficiency and speed improvements compared to existing methods.
Main Methods:
- Utilized zone plates to create X-ray point sources with synchrotron radiation from BESSY II.
- Employed a divergent light cone generated by the zone plate for holographic microscopy.
- Examined critical point dried diatoms (Navicula perminuta) and human cells at 250 eV photon energy.
Main Results:
- Successfully generated high-flux X-ray point sources using zone plates.
- Achieved holographic microscopy of biological samples with improved efficiency.
- Reduced exposure times by two orders of magnitude compared to pinhole-based methods.
Conclusions:
- Zone plates are effective for creating X-ray point sources for digital holography.
- This technique significantly enhances the speed of X-ray microscopy for biological imaging.
- The method holds promise for high-resolution, low-damage imaging of sensitive biological structures.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
X-ray Imaging
German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with X-rays, and by 1900, X-ray was widely...
X-ray Diffraction of Biological Samples
X-ray diffraction or XRD is an analytical tool that utilizes X-rays to study ordered structures such as crystalline organic and inorganic samples, polycrystalline materials, proteins, carbohydrates, and drugs.
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...

