Related Experiment Video
Updated: May 31, 2026

Transcanalicular Diode Laser-assisted Dacryocystorhinostomy for the Treatment of Primary Acquired Nasolacrimal Duct Obstruction
Published on: October 13, 2017
Monocanalicular intubation in external dacryocystorhinostomy
Efstathios T Detorakis1, Ioannis Mavrikakis, Konstantinos Ioannakis
1Department of Ophthalmology, University Hospital of Heraklion, Crete. detorakis@hotmail.com
Purpose:
To examine the feasibility of monocanalicular intubation in external dacryocystorhinostomy (EX-DCR).
Methods:
Monocanalicular intubation using the mini-Monoka tube (S1-1500u, FCI Ophthalmics, Marshfield Hills, MA, U.S.A.) was performed in 18 patients undergoing EX-DCR. The tube was placed at the superior canaliculus in 16 cases and at the inferior canaliculus in 2 cases and was removed 3 months postoperatively. All cases were followed for at least 6 months postoperatively.
Results:
The mini-Monoka was well tolerated in all patients. One case of spontaneous tube dislocation and 2 cases of presumed tube migration were recorded on the 15-day interval. Success rates on the 6-month interval were 88.88% (16/18), 94.44% (17/18), and 66.66% (12/18), concerning patency upon irrigation, resolution of mucopurulent epiphora, and resolution of watery epiphora, respectively.
Conclusions:
Monocanalicular intubation using mini-Monoka in EX-DCR is safe and effective. The technique may have advantages over bicanalicular intubation, such as easier insertion and removal, easier probing and irrigation though the unintubated canaliculus and, more importantly, less risk of punctal or corneal damage.
Related Concept Videos
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes: