Related Experiment Video
Updated: May 31, 2026

DUCT: Double Resin Casting followed by Micro-Computed Tomography for 3D Liver Analysis
Published on: September 28, 2021
Radiological examinations of the anatomy of the inferior turbinate using digital volume tomography (DVT)
L Balbach1, V Trinkel, C Guldner
1Department of Otorhinolaryngology, Head and Neck Surgery, UKGM, Marburg, Germany.
Background:
Since the last 120 years there were only few descriptions of the anatomical sizes of the inferior turbinate in the literature. On this background the current study should evaluate the radiological dimensions of the inferior turbinate and the septum using DVT.
Methods:
The latest generation of the Accu-I-tomo was used. The data of 100 adult patients have been evaluated.
Results:
The bony length was found to be 38.9 mm, the mucosal length 51.0 mm. The findings of the total mucosal thickness at different measuring points were between 8.1 mm and 10.9 mm, those of the bony thickness were between 0.9 mm and 2.3 mm and those of the bony height were between 3.9 mm and 20.8 mm.
Conclusion:
The results of this radiological study are able to point out the importance of preoperative anatomical evaluation of radiological images. The preoperative focus on the individual anatomy is very important because of the choice of an adequate surgical treatment. Today new radiological techniques can help to find out whether the reason for hypertrophied turbinates is caused by bone, mucosa or both. This knowledge enables a concerted treatment concept.