Calibration mode influences central blood pressure differences between SphygmoCor and two newer devices, the
Mohammad-Reza Rezai1, Guillaume Goudot, Conchubhair Winters
1Cardiovascular Research Group, University of Manchester and Manchester Academic Health Centre, Manchester, UK.
Abstract:
The objective of this study was to compare central systolic blood pressure (cSBP) and augmentation index (AIx) from two recently introduced devices, Omron HEM-9000 (OM) and Arteriograph (AG), not using a transfer function with those of the widely used SphygmoCor (SC) calibrated on brachial blood pressure like OM. Random-order manufacturer-recommended measurements using SC and OM by radial tonometry and AG were taken on the left arm in 35 men (54±10 years) after 5 min supine rest. Results are means (95% confidence interval) of differences using paired t-tests. cSBP by OM was 4.1 (1.0-7.1) mm Hg higher than by AG. Both OM and AG estimated the mean cSBP to be significantly higher than did SC (114.8 mm Hg) by 12.5 (10.3-14.7) and 8.6 (4.9-12.3) mm Hg, respectively, although closely correlating with SC (r=0.9). Calibrating SC with diastolic blood pressure (DBP) and more accurate mean arterial pressure (as DBP+0.4 × PP) resulted in significantly higher cSBP statistically not different from AG's cSBP: 0.9 (-1.1 to +2.9) mm Hg, and closer to OM's: 5.1 (3.4-6.8) mm Hg. Radial AIx from SC and OM disagreed by 3 (0.7-5.4)%, and correlated (r=0.8) with AG's brachial AIx. AG's aortic AIx was 7.9 (5.7-10.2)% higher than SC's, but closely correlated (r=0.9). Clinically significant, higher cSBP measured by AG, OM and more accurately calibrated SC adds to previous data suggesting that SC measurements by classic calibration underestimate cSBP. Invasive studies involving all three devices would be more illuminating.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Errors occurring during blood pressure monitoring
Several factors...
Pre-Procedural Guidelines for Assessing Blood Pressure