Related Experiment Video
Updated: May 31, 2026

Simultaneous Affinity Enrichment of Two Post-Translational Modifications for Quantification and Site Localization
Published on: February 27, 2020
Simultaneous quantitation of histamine and its major metabolite 1-methylhistamine in brain dialysates by using
E Bourgogne1, F-X Mathy, D Boucaut
1Non Clinical Development Department, UCB Pharma SA, Braine L'Alleud, Belgium. emmanuel.bourgogne@parisdescartes.fr
Abstract:
In nonclinical drug development targeting the central nervous system (CNS), the quantitative determination of extracellular brain concentrations of neurotransmitters is a key challenge. In some CNS disorders, the monitoring of the modified profile of neurotransmitter release such as that of histamine may explain the mechanism of action of the drug candidate. Microdialysis is a commonly used method for sampling extracellular levels of neurotransmitters/drug candidates in small laboratory animals. Detection and quantification of extracellular levels of neurotransmitters remain an analytical and technical challenge owing to the low concentrations of neurotransmitters collected, the small microdialysis sample size, and the high amount of inorganic salts. A precolumn derivatization strategy prior to hydrophilic interaction liquid chromatography (HILIC)-tandem mass spectrometry analysis is proposed to quantify histamine release after administration of a CNS research compound. Derivatization using propionic anhydride dissolved in organic solvent combined with the HILIC approach effectively eliminated three time-consuming steps, organic layer transfer, dry down, and reconstitution, all of which are required by traditional reversed-phase liquid chromatography. The formation of propionylated amides, performed under mild conditions, required no further sample cleanup. After a dual microdialysis probe implantation into the prefrontal cortex (neurotransmitters) and in the inferior vena cava of rat (drug candidate), microdialysate fractions were collected every 15 min for 8 h and stored frozen at -20 °C until analysis. The method was validated using 10 μL microdialysate, achieving low limits of quantitation of 83.4 and 84.5 pg.mL(-1) for histamine and 1-methylhistamine, respectively. These limits were suitable to assess kinetic release of neurotransmitters and are compatible with those obtained by microdialysis sampling. This method provided the required selectivity, sensitivity, accuracy, and precision to assess release kinetics of histamine and 1-methylhistamine in several hundred rat brain microdialysates after intravenous infusion of CNS drug candidates.
More Related Videos
11:09An HS-MRM Assay for the Quantification of Host-cell Proteins in Protein Biopharmaceuticals by Liquid Chromatography Ion Mobility QTOF Mass Spectrometry
Published on: April 17, 2018
10:54Extraction of Histones from Clinical Specimens for Epigenetic Profiling by Mass Spectrometry
Published on: November 21, 2025