Related Experiment Video
Updated: May 31, 2026

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Visual and numerical methods to measure patient skin doses in interventional procedures using radiochromic XR-RV2
R Sánchez1, E Vano, J M Fernández
1Medical Physics Service, San Carlos University Hospital, Madrid, Spain. rmsanchez.hcsc@salud.madrid.org
Abstract:
Radiochromic XR-RV2 films are considered as one of the best dosemeters to measure patient skin doses in fluoroscopy-guided interventional procedures. To fulfil this purpose, they need to be calibrated with diagnostic energies and doses beyond several Gray. The vendor provides a visual calibration strip to estimate the absorbed dose. Differences between visual dose estimation versus film digitisation were investigated. The influence of backscatter radiation on film sensitivity was also investigated and the sources of uncertainty were analysed when skin doses were measured with these films. When based on the visual comparison with the strip, the estimation of the dose resulted in an error of 50 % (2 Gy in the region around 4 Gy). However, when using numerical methods after film digitisation, the uncertainty in dose measurement fell to 7-14 % in the dose range of interest. Calibration under backscatter conditions demonstrates that the 'in air' calibration underestimates the doses by 7 %. When the dose was measured with a calibration method based on 16 bits grey digitisation, uncertainty was twice higher than when the red channel from red, green, blue digitised images was used.
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
X-ray Imaging
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...