Related Experiment Video
Updated: May 31, 2026

Physiology Lab Demonstration: Glomerular Filtration Rate in a Rat
Published on: July 26, 2015
Pitfalls of using estimations of glomerular filtration rate in an intensive care population
1Department of Internal Medicine and Aged Care, Cancer Care Services, Royal Brisbane and Women's Hospital, Brisbane, Queensland, Australia. j.martin4@uq.edu.au
Background:
Accurate knowledge of the glomerular filtration rate (GFR) is imperative in the intensive care unit (ICU) as renal status is important for medical decisions, including drug dosing.
Aims:
Recently, an estimation of GFR (eGFR) was suggested as a method of estimating GFR. How well this formula predicts GFR in unwell patients with normal initial serum creatinine concentrations has not been examined.
Methods:
The accuracy of the eGFR (before and after adjustment for actual body surface area (BSA)) was compared with measured and with estimated creatinine clearance using the Cockcroft Gault (CG) formula adjusted for total and lean body weight.
Results:
A total of 237 observations was recorded in 47 subjects. These were initially analysed independently, and then using the first observation only. Overall the mean difference between measured creatinine clearance and eGFR was -12 mL/min (95% confidence interval (CI) -20 to -3), between measured creatinine clearance and CG +17 mL/min (95% CI 9-24), between measured creatinine clearance and CG adjusted for ideal body weight +12 mL/min (95% CI 4-21) and between measured creatinine clearance and eGFR 'unadjusted' for BSA 5 mL/min (95% CI -2-13).
Conclusions:
Using either eGFR or CG formulae to estimate renal function in ICU subjects with normal serum creatinine concentrations is inaccurate. Although correcting for BSA improves the eGFR, this requirement to measure height and weight removes a major attraction for its use. We suggest that eGFR should not be automatically calculated in the ICU setting.
Related Concept Videos
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Pharmacokinetics in Geriatric Patients: Effect of Age on Drug Excretion
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant