Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Universal method for online enrichment of target compounds in capillary gas chromatography using in-oven cryotrapping
Sung-Tong Chin1, Bussayarat Maikhunthod, Philip J Marriott
1Centre for Green Chemistry, School of Chemistry, Monash University, Wellington Road, Clayton 3800, Australia.
Abstract:
A method is described that permits automated online enrichment of injected compounds in multidimensional gas chromatography by using a microfluidic heart-cut (H-C) device to direct target compounds into a cryogenically cooled internal trap (cryotrap, CT). By performing multiple injections of a sample, selected compounds or regions of a primary column separation can be collected in the CT. Remobilizing the trapped species allows elution and further resolution on the second column. Using a well-balanced H-C device, compounds can be fully excluded from the collection step or quantitatively transferred to the CT. Peak areas of the remobilized compound correlate well with the number of sample injections. Trapping on various column phases shows the method is suited to quantitative trapping of alkanes of mass greater than about dodecane and fatty acid methyl esters greater than the C8 homologue. Caffeine and menthol standards of concentration 100 μg mL(-1) gave peak area correlation coefficients for 1-10 and 1-50 replicate split injections of 1 μL volume of 0.999 and 0.996, respectively. Peak height correlations were less favorable as a result of peak broadening on the second column, presumably due to overloading at greater collected mass. The method was applied to 0.2% solutions of peppermint oil (menthol; a major component; 44%) and 1.0% lavender oil (α-terpineol and neryl acetate; minor components of 1.05 and 0.42% abundance). The minor components gave good area and height correlations, and good recovery around 90% was observed for menthol compounds recovered from 15 accumulations. Response amplification was further demonstrated for menthol from mint oil headspace sampling using solid phase microextraction. This approach should be a valuable adjunct for improved detection specificity, for detectors of low sensitivity, and when prior sample concentration provides insufficient response of selected target analytes.
More Related Videos
05:48Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
09:38Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures
Published on: January 7, 2019
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...