Updated: May 30, 2026

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring
Published on: December 9, 2010
Chemical shift sodium imaging in a mouse model of thromboembolic stroke at 9.4 T
Patrick M Heiler1, Friederike L Langhauser, Friedrich Wetterling
1Computer Assisted Clinical Medicine, Heidelberg University, Mannheim, Germany. patrick.heiler@medma.uni-heidelberg.de
Purpose:
To estimate changes in the (23)Na density and in the (23)Na relaxation time T(2) * in the anatomically small murine brain after stroke.
Materials And Methods:
Three-dimensional acquisition weighted chemical shift imaging at a resolution of 0.6 × 0.6 × 1.2 mm(3) was used for sodium imaging and relaxation parameter mapping. In vivo measurements of the mouse brain (n = 4) were performed 24 hours after stroke, induced by microinjection of purified murine thrombin into the right middle cerebral artery. The measurement time was 14 minutes in one mouse and 65 minutes in the other three. An exponential fit estimation of the free induction decay was calculated for each voxel enabling the reconstruction of locally resolved relaxation parameter maps.
Results:
The infarcted areas showed an increase in sodium density between 160% and 250%, while the T(2) * relaxation time increased by 5%-72% compared to unaffected contralateral brain tissue.
Conclusion:
(23)Na chemical shift imaging at a resolution of 0.6 × 0.6 × 1.2 mm(3) enabled sodium imaging of the anatomical small mouse brain and the acquired data allowed calculating relaxation parameter maps and hence a more exact evaluation of sodium signal changes after stroke.