Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
The reliability and accuracy of an electromagnetic motion analysis system when used conjointly with an accelerometer
D C Ribeiro1, G Sole, J H Abbott
1University of Otago, Dunedin, New Zealand. daniel.cury.ribeiro@gmail.com
Abstract:
The effect of an accelerometer driven electronic postural monitor (Spineangel®) placed within the electromagnetic measurement field of the Polhemus Fastrak™ is unknown. This study assessed the reliability and accuracy of Fastrak™ linear and angular measurements, when the Spineangel® was placed close to the sensor(s) and transmitter. Bland Altman plots and intraclass correlation coefficient (2,1) were used to determine protocol reproducibility and measurement consistency. Excellent reliability was found for linear and angular measurements (0.96, 95% CI: 0.90-0.99; and 1.00, 95% CI: 1.00-1.00, respectively) with the inclusion of Spineangel®; similar results were found, without the inclusion of Spineangel®, for linear and angular measurements, (0.96, 95% CI: 0.89-0.99; and 1.00, 95% CI: 1.00-1.00, respectively). The greatest linear discrepancies between the two test conditions were found to be less than 3.5 mm, while the greatest angular discrepancies were below 3.5°. As the effect on accuracy was minimal, these findings support the conjoint use of the Fastrak™ during validation studies of the Spineangel® device. STATEMENT OF RELEVANCE: Although previous studies have used the Fastrak™ as the gold standard measurement system, the influence of an accelerometer driven postural monitor on accuracy has not been reported. The strength of the present study has been to determine the effect of accelerometer placement within the electromagnetic field on the reliability and accuracy of the Fastrak™.
Related Concept Videos
Relative Motion Analysis - Acceleration
Relative Motion Analysis using Rotating Axes - Acceleration
Time differentiation is...
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...
Mass Analyzers: Overview
Relative Motion Analysis - Velocity
When an external force is exerted, it sets the crank into a rotational movement. This, in turn, instigates the motion of the connecting rod, leading to what is referred to as a general plane motion. This process involves two key points - point A on the connecting rod...
Mass Analyzers: Common Types