Related Experiment Video
Updated: May 30, 2026

Holistic Facial Composite Creation and Subsequent Video Line-up Eyewitness Identification Paradigm
Published on: December 24, 2015
An evaluation of the underlying mechanisms of bloodstain pattern analysis error
Nima Behrooz1, Lee Hulse-Smith, Sanjeev Chandra
1Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Road, Toronto, Ontario M5S 3G8, Canada.
Abstract:
An experiment was designed to explore the underlying mechanisms of blood disintegration and its subsequent effect on area of origin (AO) calculations. Blood spatter patterns were created through the controlled application of pressurized air (20-80 kPa) for 0.1 msec onto suspended blood droplets (2.7-3.2 mm diameter). The resulting disintegration process was captured using high-speed photography. Straight-line triangulation resulted in a 50% height overestimation, whereas using the lowest calculated height for each spatter pattern reduced this error to 8%. Incorporation of projectile motion resulted in a 28% height underestimation. The AO xy-coordinate was found to be very accurate with a maximum offset of only 4 mm, while AO size calculations were found to be two- to fivefold greater than expected. Subsequently, reverse triangulation analysis revealed the rotational offset for 26% of stains could not be attributed to measurement error, suggesting that some portion of error is inherent in the disintegration process.
More Related Videos
05:19Evaluation of Blood-Brain Barrier Breakdown in a Mouse Model of Mild Traumatic Brain Injury
Published on: October 18, 2024
07:20A Novel Approach to Overcome Movement Artifact When Using a Laser Speckle Contrast Imaging System for Alternating Speeds of Blood Microcirculation
Published on: August 30, 2017
Related Concept Videos
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Theory of Attribution II: Kelley's Covariation Theory
Errors occurring during blood pressure monitoring
Several factors...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Mechanistic Models: Compartment Models in Individual and Population Analysis
Eyewitness Memory
One such error is memory distortion, which occurs because human memory does not function like a...