Related Experiment Video
Updated: May 30, 2026

Preparation of Highly Porous Coordination Polymer Coatings on Macroporous Polymer Monoliths for Enhanced Enrichment of Phosphopeptides
Published on: July 14, 2015
Metal-organic-framework-based tandem molecular sieves as a dual platform for selective microextraction and
Na Chang1, Zhi-Yuan Gu, He-Fang Wang
1Research Center for Analytical Sciences, College of Chemistry, and State Key Laboratory of Medicinal Chemical Biology, Nankai University, Tianjin, China.
Abstract:
Metal-organic frameworks (MOFs) were employed to design tandem molecular sieves as a dual platform for selective solid-phase microextraction (SPME) and high-resolution gas chromatographic (GC) separation of target analytes in complex matrixes. An elegant combination of a ZIF-8-coated fiber for SPME with a ZIF-8-coated capillary for GC allows selective extraction and separation of n-alkanes from complex matrixes such as petroleum-based fuel and biological fluids. The proposed tandem ZIF-8 molecular sieves not only offered good enhancement factors from 235 (hexane) to 1212 (nonane), but also exhibited wide linearity with 3 orders of magnitude for the tested linear alkanes. The limits of detection for the linear alkanes ranged from 0.46 ng L(-1) (nonane) to 1.06 ng L(-1)(hexane). The relative standard deviations of retention time, peak area, peak height, and half peak width for five replicate determinations of the tested n-alkanes at 30 ng L(-1) were 0.02-0.26%, 1.9-8.6%, 1.4-6.0%, and 1.3-7.2%, respectively. The developed tandem ZIF-8 molecular sieves were further used for the determination of linear alkanes in petroleum-based fuel and human serum. The large diversity in structure and pore size allows various combinations of MOFs for designing an MOF-based tandem molecular sieve platform to achieve different selectivities in extraction and chromatographic separation and to solve headache problems in complex real sample analysis.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Extraction: Advanced Methods