Related Experiment Video
Updated: May 30, 2026

Donor Posterior Atrial Flap Rotation for Left Atrial Cuff Reconstruction in Lung Transplantation
Published on: October 11, 2024
Hardware preservation after sternal wound infection in a lung transplant recipient
Jordan V Jacobs1, Tony N Hodges, Ross M Bremner
1Department of General Surgery, Center for Thoracic Transplantation, the Heart & Lung Institute of Saint Joseph's Hospital and Medical Center, Phoenix, Arizona 85013, USA. jordan.jacobs@chw.edu
Abstract:
Sternal wound infections can result in significant morbidity and mortality. Managing these complications is particularly challenging when infected hardware is involved. Traditional thinking mandates removal of infected hardware, yet this hardware is often essential to chest wall stability in the early postoperative period. Here, we present a case of an infected transverse sternotomy wound involving hardware in a lung transplant patient whose treatment included successful hardware preservation. Our experience and other experiences reported in the literature highlight the alternatives in the management of this complication.