Detection and quantification of coronary atherosclerotic plaque by 64-slice multidetector CT: a systematic head-to-head comparison with intravascular ultrasound
Related Experiment Video
Updated: May 30, 2026

Intravascular Ultrasound Image-Based Finite Element Modeling Approach for Quantifying In Vivo Mechanical Properties of Human Coronary Artery
Published on: December 6, 2024
Stella-Lida Papadopoulou1, Lisan A Neefjes, Michiel Schaap
1Department of Cardiology, Erasmus University Medical Center, PO Box 2040, 3000 CA, Rotterdam, The Netherlands. elpa98@gmail.com
Objective:
We evaluated the ability of 64-slice multidetector computed tomography (MDCT)-derived plaque parameters to detect and quantify coronary atherosclerosis, using intravascular ultrasound (IVUS) as the reference standard.
Methods:
In 32 patients, IVUS and 64-MDCT was performed. The MDCT and IVUS datasets of 44 coronary arteries were co-registered using a newly developed fusion technique and quantitative parameters were derived from both imaging modalities. The threshold of >0.5 mm of maximum wall thickness was used to establish plaque presence on MDCT and IVUS.
Results:
We analyzed 1364 coregistered 1-mm coronary cross-sections and 255 segments of 5-mm length. Compared with IVUS, 64-MDCT enabled correct detection in 957 of 1109 cross-sections containing plaque (sensitivity 86%). In 180 of 255 cross-sections atherosclerosis was correctly excluded (specificity 71%). On the segmental level, MDCT detected 213 of 220 segments with any atherosclerotic plaque (sensitivity 96%), whereas the presence of any plaque was correctly ruled out in 28 of 32 segments (specificity 88%). Interobserver agreement for the detection of atherosclerotic cross-sections was moderate (Cohen's kappa coefficient K=0.51), but excellent for the atherosclerotic segments (K=1.0). Pearson's correlation coefficient for vessel plaque volumes measured by MDCT and IVUS was r=0.91 (p<0.001). Bland-Altman analysis showed a slight non-significant underestimation of any plaque volume by MDCT (p=0.5), with a trend to underestimate noncalcified and overestimate mixed/calcified plaque volumes (p=0.22 and p=0.87 respectively).
Conclusion:
MDCT is able to detect and quantify atherosclerotic plaque. Further improvement in CT resolution is necessary for more reliable assessment of very small and distal coronary plaques.
More Related Videos
04:40Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
10:02Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT)
Published on: May 2, 2012
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Acute Coronary Syndrome III: Diagnostic Studies