Related Experiment Video
Updated: May 30, 2026

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Nickel-titanium shape-memory sawtooth-arm embracing fixator for periprosthetic femoral fractures
Xin Zhao1, Zhen-An Zhu, Yue-Hua Sun
1Department of Orthopaedic Surgery, Ninth People's Hospital, Shanghai JiaoTong University School of Medicine, 639 Zhizaoju Road, Shanghai, 200011, People's Republic of China.
Purpose:
We reviewed data to determine outcomes for 21 consecutive Vancouver type B1 or type C periprosthetic fractures that we treated between 2001 and 2008 using a nickel-titanium shape-memory sawtooth-arm embracing fixator.
Methods:
The study participants were 12 men and 9 women (mean age, 70.8 years; range, 42-85 years). The average duration of follow-up monitoring was 39.7 months (range, 1-78 months). In five cases, cables and screws were used for further stabilisation. No bone grafting was performed for any of the patients.
Results:
Results were satisfactory, except for one patient who died one month after surgery from a cause unrelated to arthroplasty. Bone union was achieved in the remaining 20 cases within an average of 5.25 months. No implant failures or malunions occurred in any of the patients. The average Harris hip score at the final follow-up examination was 79.3 points.
Conclusions:
Our results show that the embracing fixator is a valid alternative treatment for Vancouver type B1 or type C periprosthetic femoral fractures.
More Related Videos
10:09Adjustable Stiffness, External Fixator for the Rat Femur Osteotomy and Segmental Bone Defect Models
Published on: October 9, 2014
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015