Related Experiment Video
Updated: May 30, 2026

Using Extraordinary Optical Transmission to Quantify Cardiac Biomarkers in Human Serum
Published on: December 13, 2017
An integrated chip for rapid, sensitive, and multiplexed detection of cardiac biomarkers from fingerprick blood
Guo-Jun Zhang1, Zhan Hong Henry Luo, Min Joon Huang
1Institute of Microelectronics, A*STAR (Agency for Science, Technology and Research), 11 Science Park Road, Singapore 117685, Singapore. gjzhangtj@hotmail.com
Insights
This study introduces an integrated chip for rapid, sensitive detection of three cardiac biomarkers from fingerprick blood. The novel device offers a faster, more efficient alternative to traditional methods for diagnosing heart attack patients.
Area of Science:
- Biomedical Engineering
- Nanotechnology
- Cardiovascular Diagnostics
Background:
- Cardiovascular diseases are a leading cause of adult mortality globally.
- Electrocardiogram (ECG) lacks sensitivity for early detection.
- Current cardiac biomarker assays (e.g., ELISA) are time-consuming, require large samples, and are not suitable for rapid point-of-care testing.
Purpose of the Study:
- To develop an integrated chip for rapid, sensitive, and simultaneous analysis of multiple cardiac biomarkers.
- To overcome the limitations of existing diagnostic methods for acute cardiac events.
- To enable point-of-care testing using minimal blood volume.
Main Methods:
- Fabrication of an integrated chip combining a plasma filtration unit and a silicon nanowire (SiNW) array sensor.
- Simultaneous detection of troponin T (cTnT), creatine kinase MM (CK-MM), and creatine kinase MB (CK-MB) using antibody-spotted SiNWs.
- Utilized fingerprick blood (2 μl) for analysis, minimizing sample volume and processing time.
Main Results:
- The integrated chip successfully performed plasma separation and simultaneous detection of three cardiac biomarkers.
- Achieved a low detection limit of 1 pg/ml for cTnT, CK-MM, and CK-MB.
- Completed the analysis within 45 minutes from a small blood sample.
Conclusions:
- The developed integrated chip offers a rapid, sensitive, and simultaneous method for cardiac biomarker detection.
- This technology has the potential to significantly improve the diagnosis and management of heart attack patients.
- The chip design minimizes sample volume and processing time, making it suitable for point-of-care applications.
Abstract:
Cardiovascular diseases are the major cause of death among adults worldwide. Electrocardiogram (ECG) is a first test when a patient suffering from chest pain sees a doctor, however, it is lack of the required sensitivity. Standard assays to detect cardiac biomarkers, like enzyme-linked immunosorbent assay (ELISA) are sensitive, but suffer from important sample and reagent consumption in large-scale studies. Moreover they are performed in central laboratories of clinics and hospitals and take a long time, which is highly incompatible with the quick decisions needed to save a heart attack patient. Herein, we describe an integrated chip allowing rapid, sensitive, and simultaneous analysis of three cardiac biomarkers in fingerprick blood. The integrated chip is composed of a filtration chip for plasma separation from blood and a silicon nanowire (SiNW) array sensor chip for protein detection. These two chips are fabricated separately and bonded to form a single unit after alignment. The integrated chip is capable of reducing the dead volume of the sample by eliminating the tubing between the two chips. After the plasma is filtrated by the filtration chip, the SiNW sensor, spotted with three different antibodies, enabled us to detect three cardiac biomarkers, troponin T (cTnT), creatine kinase MM (CK-MM) and creatine kinase MB (CK-MB), simultaneously. The integrated chip is able to attain a low detection limit of 1 pg/ml for the three cardiac biomarkers from 2 μl blood in 45 min.
More Related Videos
08:58Fully Automated Centrifugal Microfluidic Device for Ultrasensitive Protein Detection from Whole Blood
Published on: April 16, 2016
10:12A Sensitive and Specific Quantitation Method for Determination of Serum Cardiac Myosin Binding Protein-C by Electrochemiluminescence Immunoassay
Published on: August 8, 2013