Related Experiment Videos

Impact of sirolimus-eluting stent fracture on 4-year clinical outcomes

Hisashi Umeda1, Tomoko Kawai, Naoki Misumida

  • 1Division of Cardiology, Toyota Memorial Hospital, 1-1 Heiwa-cho, Toyota, Japan. hisashi_umeda_aa@mail.toyota.co.jp

Insights

Stent fracture (SF) after sirolimus-eluting stent (SES) implantation increases major adverse cardiac events (MACE) within the first year. However, SF did not significantly impact MACE rates between 1 and 4 years post-procedure.

Area of Science:

  • Cardiovascular Medicine
  • Interventional Cardiology
  • Biomedical Engineering

Background:

  • Stent fracture (SF) is a known complication of sirolimus-eluting stent (SES) implantation.
  • The association between SF and long-term major adverse cardiac events (MACE) after SES remains unclear, particularly beyond one year.

Purpose of the Study:

  • To evaluate the impact of stent fracture (SF) versus non-fracture on 4-year clinical outcomes in patients treated with sirolimus-eluting stents (SES).
  • To assess the temporal relationship between SF and MACE, specifically examining outcomes within the first year and between years 1 and 4.

Main Methods:

  • Analysis of 874 lesions in 793 patients who underwent SES implantation and 6- to 9-month angiographic follow-up.
  • Identification of stent fracture (SF) at follow-up and comparison of clinical outcomes (MACE, target-lesion revascularization, stent thrombosis, death, myocardial infarction) between SF and non-SF groups over 4 years.

Main Results:

  • Stent fracture (SF) was identified in 8.0% of lesions.
  • SF lesions showed significantly higher in-stent late loss and in-stent restenosis rates compared to non-SF lesions.
  • At 4 years, SF was associated with significantly higher MACE (23.2% vs. 12.6%, P=0.014) and target-lesion revascularization (18.8% vs. 10.2%, P=0.029) rates.
  • The adverse impact of SF on MACE was primarily observed within the first year (17.4% vs. 6.6%, P=0.001), with similar MACE rates between 1 and 4 years (5.8% vs. 5.9%, P=0.611).
  • No significant differences were found in very late stent thrombosis, death, or myocardial infarction between SF and non-SF groups.

Conclusions:

  • Stent fracture (SF) of sirolimus-eluting stents (SES) is linked to increased MACE, predominantly driven by target-lesion revascularization, within the first year post-implantation.
  • Beyond the first year, stent fracture (SF) did not show a significant association with major adverse cardiac events (MACE) in this cohort.
Abstract