Related Experiment Video
Updated: May 30, 2026

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Transition from screen-film to computed radiography in a paediatric hospital: the missing link towards optimisation
Graciano Paulo1, Joana Santos, Ana Moreira
1College of Health Technology of the Polytechnic Institute of Coimbra, Coimbra, Portugal. graciano@estescoimbra.pt
Abstract:
In paediatrics, the risks associated with ionising radiation should be a major concern, due to children's higher susceptibility to radiation effects. Measure entrance skin dose (ESD) in chest and pelvis X-ray projections and compare the results with the 'European guidelines on quality criteria for diagnostic radiographer images in paediatrics' in order to optimise radiological practice. ESD values were obtained using an ionisation chamber Diamentor M4 KDK (PTW) in 429 children, who underwent chest X-ray or pelvis X-ray in a Computed Radiography system. In the first phase of the study, data were collected according to protocols used in the department; in a second phase different tube voltage values were used according to patient weight. A third phase was carried out, only for chest X-ray, using the exposure parameters of phase 2, plus activating lateral ionisation chamber. Three paediatric radiologists blindly assessed image quality of chest X-ray, using a validated assessment available in the 'European guidelines on quality criteria for diagnostic radiographer images in paediatrics'. Considering all the patients submitted to chest X-ray, the average ESD was 0.22, 0.16 and 0.08 mGy, for phases 1, 2 and 3, respectively. For pelvis X-ray, the average ESD decreased from 1.18 mGy in phase 1 to 0.78 mGy in phase 2. Dose optimisation was achieved. ESD was reduced 63.6 and 33.9 % in chest and pelvis X-ray, respectively.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
X-ray Imaging
