Endoscopic Septoplasty with Limited Two-line Resection: Minimally Invasive Surgery for Septal Deviation
Published on: June 20, 2018
Stenting the nasal airway for maximizing inspiratory airflow: internal Max-Air Nose Cones versus external Breathe
1Department of Psychology, Human Psychophysiology Laboratory, Wheeling Jesuit University, Wheeling, WV 26003, USA. raudenbc@wju.edu
Background:
Several nasal dilator devices designed to stent the anterior nasal airway to increase peak nasal inspiratory flow (PNIF) currently exist; however, comparisons of such devices are limited. This study was designed to compare the efficacy of two different nasal dilator devices, an internal device (Max-Air Nose Cones; Sanostec Corp., Beverly Farms, MA) and an external device (Breathe Right nasal strip; GlaxoSmithKline, Brentford, Middlesex, U.K.) on stenting of the anterior nasal airway to maximize PNIF.
Methods:
Repeated measurements of PNIF were obtained in 30 individuals noting complaints of sleep-disordered breathing due to nasal breathing discomfort and nasal airway obstruction, both with and without the two different nasal dilator devices.
Results:
A one-within analysis of variance (ANOVA) was performed among the three conditions (control, Max-Air Nose Cones, and Breathe Right nasal strip), and a statistically significant effect was found (F[2,58] = 298.13; p< 0.00001). Tukey post hoc contrasts revealed that the control condition PNIF (66.07 L/min) was significantly lower than both the Max-Air Nose Cones (138.73 L/min) and the Breathe Right nasal strip (102.17 L/min) conditions. The Max-Air Nose Cone increased inspiratory airflow by 73 L/min, or a 110% improvement over baseline. In addition, the Max-Air Nose Cone condition PNIF was significantly higher than both the control condition and the nasal strip condition.
Conclusion:
Although both the Max-Air Nose Cones and the Breathe Right nasal strips increased PNIF from baseline, the Max-Air Nose Cones showed significantly greater efficacy at stenting the anterior nasal airway, providing twice the improvement in PNIF over baseline than did the Breathe Right nasal strips.
Related Concept Videos
Nose and Nasal Cavity
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils, connected...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Suctioning the Nasopharyngeal Airway
Equipment Required
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Epistaxis
Etiology
Possible causes of this condition include high blood pressure, trauma, low humidity, upper respiratory tract infections, allergies, foreign bodies, nasal inhalation of corticosteroids or illicit drugs, excessive use of decongestant nasal sprays, facial or nasal surgery, anatomic malformation, tumors, or systemic...