Intraoperative distal graft end-diastolic velocity (EDV) measured by completion duplex ultrasound (CDU) predicts crural bypass patency in critical limb ischemia (CLI) patients. Grafts with EDV <5 cm/s face high failure risk, highlighting CDU
Area of Science:
- Vascular Surgery
- Medical Imaging
- Critical Limb Ischemia Research
Background:
- Critical limb ischemia (CLI) poses significant challenges for limb salvage.
- Crural bypass grafting is a key revascularization strategy for CLI.
- Predictive markers for bypass graft patency are crucial for optimizing outcomes.
Purpose of the Study:
- To evaluate intraoperative distal graft end-diastolic velocity (EDV) using completion duplex ultrasound (CDU) as a predictor of crural bypass patency.
- To identify factors influencing graft patency and failure in CLI patients.
Main Methods:
- Retrospective review of 116 patients undergoing crural revascularization with vein conduit and CDU.
- Analysis of graft patency at 1 year using Kaplan-Meier and Cox proportional hazards models.
- Correlation of distal graft EDV with modified Rutherford scores and other clinical variables.
Main Results:
- One-year primary patency rates varied significantly with distal graft EDV tertiles (32% for <5 cm/s, 64% for 5-15 cm/s, 84% for >15 cm/s).
- Low distal graft EDV (<5 cm/s), poor conduit quality, age <70, and lack of statin use were independent predictors of graft failure.
- Predictors of low EDV included single-vessel runoff, poor conduit, and diabetes.
Conclusions:
- Intraoperative distal graft EDV measured by CDU is a valuable predictor of crural vein graft patency in CLI patients.
- Grafts with EDV <5 cm/s are at high risk for early failure, necessitating close monitoring or intervention.
- Findings reinforce the importance of graft quality, patient factors (age, statin use), and runoff in bypass success.
Objective:
To determine if intraoperative distal graft end-diastolic velocity (EDV) using completion duplex ultrasound (CDU) predicts patency of crural bypass in patients with critical limb ischemia (CLI).
Methods:
Records of 116 non-consecutive patients who underwent crural revascularization with vein conduit and CDU between 1998 and 2008 were reviewed. Bypass grafts were performed for rest pain (34%) or tissue loss (66%), while 56% of the reported cases were categorized as "disadvantaged" because of compromised vein quality or diseased arterial outflow. A 10-MHz low-profile transducer was used to image the entire bypass at case completion. Technical adequacy of the grafts was verified by absence of retained valves, arteriovenous fistulas, or localized velocity increases and presence of bypass-dependent distal pulses. Modified Rutherford scores were calculated as surrogate markers of runoff resistance and compared to distal graft EDV. The primary study end point was graft patency during a 1-year posttreatment period. Patency rates were determined using Kaplan-Meier life table methodology and compared using the log-rank test. Predictors of graft patency were determined by Cox proportional hazards.
Results:
Primary, primary-assisted, and secondary patency for all crural bypasses were 62%, 66%, and 70% at 1 year, respectively. When stratified by tertiles of distal graft EDV (0 - <5 cm/s, 5-15 cm/s, >15 cm/s), 1-year primary patency rates were 32%, 64%, and 84% (P = .001). Low (0 - < 5 cm/s) distal graft EDV (hazard ratio [HR], 3.3 confidence interval [CI], 1.74-6.41; P < .001), poor-quality conduit (HR, 2.5; CI, 1.19-5.21; P = .016), age <70 (HR, 2.08; CI, 1.06-4.00; P = .031), and lack of statin use (HR, 2.04; CI, 1.04-4.00; P = .038) were independent predictors of graft failure. While the modified Rutherford score correlated with distal graft EDV (P = .05), it was not an independent predictor of patency (P = .58). Predictors of low EDV (<5 cm/s) included single-vessel runoff (odds ratio [OR], 3.33; CI, 1.14-9.71; P = .027), poor conduit (OR, 2.94; CI, 1.16-7.41; P = 0.024), and diabetes (OR, 2.86; CI, 1.14-7.21; P = .025).
Conclusions:
Distal graft EDV predicts crural vein graft patency in patients with CLI. Grafts with EDV <5 cm/s remain at high risk for early failure. The impacts on patency of statins, age, and poor-quality conduit are, again, confirmed. These results highlight the value of EDV using intraoperative CDU for anticipating and, possibly, improving results of open crural revascularization.
More Related Videos
Related Concept Videos
Peripheral Artery Disease V: Postoperative Nursing Management
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies