Related Experiment Video
Updated: May 30, 2026

The Effect of Ultraviolet Radiation on the Chemical Bath Deposition of Bis(thiourea) Cadmium Chloride Crystals and the Subsequent CdS Obtention
Published on: August 30, 2018
X-ray absorption fine structure of artificial antigens for cadmium
Liang Lu1, Aiping Liu, Fusheng Chen
1College of Food Science and Technology, Huazhong Agricultural University, Wuhan 430070, Hubei Province, PR China.
Abstract:
Immunoassay technology as a quick and large-scale screening method to detect metal ions in foods and environmental samples has rapidly been developed due to several advantages over conventional instrument-intensive methods. Unlike biomacromolecule, metal ions are haptens without immunogenicity, so successful preparation of artificial antigens is the first critical step for establishing immunoassay methods for them. In the current paper, cadmium ions were conjugated to BSA and OVA, respectively, using bifunctional chelator, p-SCN-Bn-DTPA. The ultraviolet analysis indicated that the maximum absorption peak of Cd-p-SCN-DTPA-BSA and Cd-p-SCN-DTPA-OVA had a small peak shift and an apparent absorbance increase compared to that of BSA and OVA, and the extents of substitution of ɛ-amino in both conjugates were 51.2% and 58.6%, respectively. In addition, the EXAFS of conjugates implied that Cd(2+) coordinated with N and O atoms of DTPA in artificial antigens, the coordination type and number of Cd-DTPA, Cd-p-SCN-Bn-DTPA-BSA, Cd-p-SCN-Bn-DTPA-OVA were the same. XANES region and geometries of the three compounds were also same. These results implied that the three antigens had the similar local structure and atomic geometry. This was the first time that the XAFS was attempted for the identification of artificial heavy metal ion antigens.
Related Concept Videos
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Determination of Crystal Structures
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...

