Partial herniation through the peritoneal defect of a pfannenstiel incision: a rare complication of non-closure
John O Larkin1, Faisal N Awan1, Adrian C McArdle1
1Department of Colorectal Surgery, St James's Hospital, Dublin, Ireland.
Background:
The Pfannenstiel incision is used almost invariably in Caesarean section. With Caesarean section rates increasing, the Pfannenstiel is a commonly performed incision. The prevailing recommendation is not to close the peritoneum when closing a Pfannenstiel incision, and peritoneal non-closure does not appear to statistically influence postoperative complication rates.
Case:
A 33-year-old woman presented with severe, intermittent lower abdominal pain one year after a Caesarean section. Laparoscopy showed a hernial defect at the Pfannenstiel incision, between the left rectus abdominis muscle and the anterior rectus sheath. Mesh repair was performed with uncomplicated postoperative outcome.
Conclusion:
The current case illustrates that complications specific to non-closure of the peritoneum do arise. We advocate that laparoscopy should be considered for any patient with persistent, severe, or atypical pain following a Pfannenstiel incision.
Related Concept Videos
Esophageal Perforation-I: Introduction
The location of esophageal perforation can vary, occurring anywhere along the esophagus.
Hiatal Hernia
Esophageal Perforation-II: Clinical Manifestations and Management
Clinical Manifestations:
Diverticular Disease of the Colon
Aneurysm III: Interprofessional Care
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications