Related Experiment Video
Updated: May 30, 2026

Echocardiographic Evaluation of Atrial Communications before Transcatheter Closure
Published on: February 8, 2022
Preoperative assessment of mitral valve prolapse and chordae rupture using real time three-dimensional
Xin Chen1, Dandan Sun, Jun Yang
1Echo Lab, Department of Cardiac Surgery, the First Affiliated Hospital of China Medical University, Shenyang, China. chen_heart@hotmail.com
Background:
Mitral valve (MV) repair provides a better outcome in patients with significant mitral regurgitation than MV replacement. Valve repair requires a thorough understanding of MV morphology. Recently developed real time three-dimensional transesophageal echocardiography (RT3D TEE) can provide online acquisition and accurate information of cardiac structures. The study aim was to evaluate the feasibility and accuracy of using RT3D TEE to assess mitral valve prolapse (MVP) and chordae rupture for surgical planning purposes.
Methods:
Fifty-six consecutive patients with moderate to severe mitral regurgitation due to MVP received two-dimensional (2D) TEE and RT3D TEE the day before operation. The accuracy of the assessment of MVP and chordae rupture by RT3D TEE was determined and compared with assessment by 2D TEE using surgical inspection as the gold standard.
Results:
The overall sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of 2D TEE in detection of MVP were 87%, 96%, 93%, 88%, and 95%, respectively, whereas those of RT3D TEE were 100%, 99%, 99%, 98%, and 100%, respectively (P<0.05 for all comparisons). The receiver operating characteristic (ROC) curve areas for assessment of anterior leaflet and posterior leaflet segment involvement using RT3D TEE (ROC areas 0.96 and 0.99) were higher than for those using 2D TEE (ROC areas 0.86 and 0.94). Interobserver agreement for RT3D TEE (κ=0.97, 95% confidence interval [CI] 0.92-1.00) was significantly greater than for 2D TEE (κ=0.89, 95% CI 0.81-0.93) (P<0.05).
Conclusion:
RT3D TEE is a feasible, accurate and reproducible method for evaluating MVP and chordae rupture in the clinical setting.
Related Concept Videos
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
Mitral Regurgitation II: Clinical Features and Diagnostic Tests
Mitral Stenosis II: Clinical features and Diagnostic Tests
Mitral Regurgitation III: Medical Management
Mitral Valve Prolapse I: Introduction