Clinically plausible hyperventilation does not exert adverse hemodynamic effects during CPR but markedly reduces
Raúl J Gazmuri1, Iyad M Ayoub, Jeejabai Radhakrishnan
1Resuscitation Institute at Rosalind Franklin University of Medicine and Science, 3333 Green Bay Road, North Chicago, IL 60064, USA. raul.gazmuri@rosalindfranklin.edu
Aims:
Ventilation at high respiratory rates is considered detrimental during CPR because it may increase intrathoracic pressure limiting venous return and forward blood flow generation. We examined whether ventilation at high, yet clinically plausible, tidal volumes could also be detrimental, and further examined effects on end-tidal pCO(2) (P(ET)CO(2)).
Methods:
Sixteen domestic pigs were randomized to one of four ventilatory patterns representing two levels of respiratory rate (min(-1)) and two levels of tidal volume (ml/kg); i.e., 10/6, 10/18, 33/6, and 33/18 during chest compression after 8 min of untreated VF.
Results:
Data (mmHg, mean ± SD) are presented in the order listed above. Ventilation at 33/18 prompted higher airway pressures (p<0.05) and persistent expiratory airway flow (p<0.05) before breath delivery demonstrating air trapping. The right atrial pressure during chest decompression showed a statistically insignificant increase with increasing minute-volume (7 ± 4, 10±3, 12 ± 1, and 13 ± 3; p=0.055); however, neither the coronary perfusion pressure (23 ± 1, 17 ± 6, 18 ± 6, and 21 ± 2; NS) nor the cerebral perfusion pressure (32 ± 3, 23 ± 8, 30 ± 12, and 31 ± 3; NS) was statistically different. Yet, increasing minute-volume reduced the P(ET)CO(2) demonstrating a high dependency on tidal volumes delivered at currently recommended respiratory rates.
Conclusions:
Increasing respiratory rate and tidal volume up to a minute-volume 10-fold higher than currently recommended had no adverse hemodynamic effects during CPR but reduced P(ET)CO(2) suggesting that ventilation at controlled rate and volume could enhance the precision with which P(ET)CO(2) reflects CPR quality, predicts return of circulation, and serve to guide optimization of resuscitation interventions.
Related Concept Videos
Hyperpnea and Hyperventilation
Chemical Factors Affecting Respiration Centers
CO2 has a potent influence on respiration and is strictly regulated. Under...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-III