Mass screening of emergency department visitors for occult radionuclide contamination
Ying Chieh Huang1, Dom-Gene Tu
1Department of Emergency Medicine, Chiayi Christian Hospital, Chiayi City, Taiwan. Galaxy.bear@msa.hinet.net
Objective:
To design an effective, efficient, and affordable radiation surveillance system to screen every emergency department (ED) visitor before they enter the ED.
Methods:
We chose fluoro-2-deoxyglucose as the source of γ-rays. We collected all available radiation dosimeters in the hospital, designed four modules of measurement, and estimated the distance from visitors to the dosimeter. The maximal distances containing 95% (D95%) of visitors were obtained for the sensitivity tests of every dosimeter in each module. The surveillance system was designed as a dual-monitor system to reduce the possibility of machinery failure. We checked system reliability, followed by a 2-year validation test.
Results:
Four dosimeters passed the dose-distance tests. For ambulatory visitors, the triage wall-mounted module had the shortest D95%, followed by the triage nurse module. For recumbent visitors, the triage nurse module had the shortest D95%, followed by the triage wall-mounted module. Area monitors showed better sensitivities than personal dosimeters; however, triage nurses could not wear them because of their size and weight. We used an area monitor on the triage post and the individual dosimeter on the triage nurse as our surveillance system. This system worked well in the reliability test. A sentinel event occurred in the validation test, with a peak dose of 49 136 nSv/h.
Conclusion:
Radiation threat to the ED, although uncommon, is real. For the safety of everyone in the ED, you can install an effective, efficient, but affordable surveillance system similar to ours if your ED is not exempted from this threat.
More Related Videos
06:28Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...